GSI Outdoors PNEG-552 service manual Unload Switch

Page 14

3. Dryer Control Panel

Unload Switch

The UNLOAD switch turns the metering rolls and discharge auger ON or OFF, and selects the operation of the metering rolls.

In the 2 Speed position, if the MOISTURE CONTROL switch is ON, and the drying mode switch is turned to continuous flow, the metering roll speed will alternate between the high speed metering roll potentiometer setting and the low speed metering roll potentiometer setting, depending on the control signal from the moisture control thermostat. The discharge auger will operate continuously.

In the 1 Speed position, if the MOISTURE CONTROL switch is ON, and the drying mode switch is turned to continuous flow, the metering roll speed will operate at the high speed metering roll potentiometer setting or turn off depending on the control signal from the moisture control thermostat. The discharge auger will operate whenever the metering rolls are operating.

In both the 1 Speed and the 2 Speed position, if the MOISTURE CONTROL switch is OFF, and the drying mode switch is turned to continuous flow, the metering roll speed can be manually controlled by adjusting the high speed metering roll potentiometer. The discharge auger will operate continuously.

If the drying mode switch is turned to staged batch, the UNLOAD switch should be set to the 1 Speed position. The discharge auger and metering rolls will only operate during the unload cycle of the staged batch operation, and the speed of the metering rolls is adjusted using the high speed metering roll potentiometer.

NOTE: If the unload auxiliary motor overload relay is being utilized in the dryer control panel, the same switch will also control the operation of the auxiliary equipment.

Low Speed Metering Roll Potentiometer

Use this to adjust the low speed of the metering roll when the 2 Speed automatic moisture control feature of the dryer is in use.

High Speed Metering Roll Potentiometer

Use this to:

Set the high speed of the metering roll when the 2 Speed automatic moisture control feature of the dryer is utilized.

Set the speed of the metering rolls when the 1 Speed automatic moisture control feature of the dryer is utilized.

Set the speed of the metering rolls during continuous flow operation when the moisture control is not used.

Set the rate of grain discharge from the dryer during the unload cycle of staged batch dryer operation.

Dryer Power Start Switch

This switch starts and operates the dryer based on switch settings. If other switch settings are in the OFF position, individual dryer components can be operated by turning the drying mode switch to continuous flow, pressing the dryer power start button and then turning on the desired dryer component.

14

PNEG-552100 Series Dryer

Image 14
Contents Series Dryer PNEG-552100 Series Dryer Contents Table of Contents Safety Guidelines Dryer Operation Emergency StopSafety Precautions Use Caution in the Operation of this EquipmentDecal DC-1224 Decal DC-889Safety Alert Decals Decal DC-972Decal DC-1229 Decal DC-1227Decal DC-1225 Regulations Decal DC-973Dryer Control Panel Dryer Control Panel Featuring the 100 Series Control System Moisture ControlUnload Switch Dryer Power Stop Switch Setting the Dry, Cool, Unload and Out of Grain Timers Monitoring Grain Temperatures, Plenum Temperature or Timers Special Features Safety Circuit Shut Down MessagesLoss of Flame Error Conditions Error Conditions Set Control Switches Inspect the Metering RollsPower Start Button Electrical PowerControl Power Switch Fuel CheckFan Switch Metering Roll OperationStaged Batch Check Burner SafetyHeater Test Fire LP Gas Natural GasRef # Description Dryer Shut DownStopping Dryer Operation Filling the Dryer Continuous Flow OperationFull Start-Up Check Fan Setting Heater Setting Fan Function Heater Function Staged Batch OperationPNEG-552 100 Series Dryer Series Batch Timer Settings Starting the DryerAdjusting the Temperature Full Heat Continuous Flow Operation Moisture % Removed pts Speed Dry Time min Low High Adjusting the Moisture ControlInitial Moisture Full Heat Approximate Seasonal Inspection and Service Hours of Service per Year Range Suggested Lube IntervalAdditional Checks Lubrication ProceduresSuggested Lubricants Insulation Class Consistency Type Grease Frame TypeRef # Description Clearance Holes Fan Propeller Removal and InstallationThreaded Bushing Holes Fan Motor Removal and Installation Fan Blade RemovalPosition of Fan Motor Heater Parts Removal and Installation Metering Roll Servicing Main ControlsHow to Determine a Metering Roll Problem As necessary. See FHow to Clear a Jammed Metering Roll Series Single Fan Wiring to Control Box Series Front Panel External Wiring Series Front Panel Internal Wiring Series Lower Back Panel Wiring Series External Wiring to Dryer Series Upper Control Box Wiring Series Main Power Wiring Series Control Schematic Series Control Schematic PNEG-552 100 Series Dryer Series 220 Volt 1 Phase Power Schematic Series 220VAC 3 Phase Power Schematic Series 440VAC 3 Phase Power Schematic Display shows Vapor High Temperature Problem Possible CausePress the dryer power start button Plenum High Temperature messages at Display shows Plenum High TemperatureDisplay shows Grain High Temperature Display shows Rear Discharge WarningTroubleshooting Wires connected together, the thermostat is faulty FAQs PNEG-552100 Series Dryer GSI Group Warranty