7. Service

How to Clear a Jammed Metering Roll

Shut down the fan/heater and eliminate any other noise when making this check. Place a pipe wrench on the hub of the sprocket of the jammed metering roll and turn the roll. First backward, and then forward several times in an attempt to dislodge the object, and clear it through the roll. If this is not successful, have an assistant turn the metering roll, and attempt to locate the jam by sound. Once the location is determined, the roll can be reached from the inside of the dryer by opening the hinged auger cover panel in that specific section. Loosen the two (2) nuts on the bolts holding the meter roll shield (also called meter roll strike off Plate in the past) and lift the shield to access the area above and behind the meter roll. If removing all the grain from this column is necessary, lift the shield to its highest position and tighten the nuts. FROM OUTSIDE THE DRYER, manually run the Unload Auger with the MOISTURE CONTROL switch turned OFF and the high speed potentiometer set to 000. This will allow the grain from that column alone to pass over the metering roll and into the auger emptying that column for complete access to the meter roll.

Never run the unload auger or the metering rolls with anyone inside the dryer.

PNEG-552100 Series Dryer

43

Image 43
Contents Series Dryer PNEG-552100 Series Dryer Contents Table of Contents Safety Guidelines Emergency Stop Dryer OperationUse Caution in the Operation of this Equipment Safety PrecautionsDecal DC-889 Decal DC-1224Decal DC-972 Safety Alert DecalsDecal DC-1225 Decal DC-1227Decal DC-1229 Decal DC-973 RegulationsDryer Control Panel Moisture Control Dryer Control Panel Featuring the 100 Series Control SystemUnload Switch Dryer Power Stop Switch Setting the Dry, Cool, Unload and Out of Grain Timers Monitoring Grain Temperatures, Plenum Temperature or Timers Safety Circuit Shut Down Messages Special FeaturesLoss of Flame Error Conditions Error Conditions Inspect the Metering Rolls Set Control SwitchesFuel Check Electrical PowerControl Power Switch Power Start ButtonMetering Roll Operation Fan SwitchLP Gas Natural Gas Burner SafetyHeater Test Fire Staged Batch CheckStopping Dryer Operation Dryer Shut DownRef # Description Full Start-Up Check Continuous Flow OperationFilling the Dryer Staged Batch Operation Fan Setting Heater Setting Fan Function Heater FunctionPNEG-552 100 Series Dryer Starting the Dryer Series Batch Timer SettingsAdjusting the Temperature Full Heat Continuous Flow Operation Initial Moisture Full Heat Approximate Adjusting the Moisture ControlMoisture % Removed pts Speed Dry Time min Low High Hours of Service per Year Range Suggested Lube Interval Seasonal Inspection and ServiceInsulation Class Consistency Type Grease Frame Type Lubrication ProceduresSuggested Lubricants Additional ChecksRef # Description Threaded Bushing Holes Fan Propeller Removal and InstallationClearance Holes Fan Blade Removal Fan Motor Removal and InstallationPosition of Fan Motor Heater Parts Removal and Installation Main Controls Metering Roll ServicingAs necessary. See F How to Determine a Metering Roll ProblemHow to Clear a Jammed Metering Roll Series Single Fan Wiring to Control Box Series Front Panel External Wiring Series Front Panel Internal Wiring Series Lower Back Panel Wiring Series External Wiring to Dryer Series Upper Control Box Wiring Series Main Power Wiring Series Control Schematic Series Control Schematic PNEG-552 100 Series Dryer Series 220 Volt 1 Phase Power Schematic Series 220VAC 3 Phase Power Schematic Series 440VAC 3 Phase Power Schematic Press the dryer power start button Problem Possible CauseDisplay shows Vapor High Temperature Display shows Rear Discharge Warning Display shows Plenum High TemperatureDisplay shows Grain High Temperature Plenum High Temperature messages atTroubleshooting Wires connected together, the thermostat is faulty FAQs PNEG-552100 Series Dryer GSI Group Warranty