GSI Outdoors service manual PNEG-552 100 Series Dryer

Page 53

9. Schematic Diagram

100 Series Control Schematic (Continued)

PNEG-552100 Series Dryer

53

Image 53
Contents Series Dryer PNEG-552100 Series Dryer Contents Table of Contents Safety Guidelines Emergency Stop Dryer OperationUse Caution in the Operation of this Equipment Safety PrecautionsDecal DC-889 Decal DC-1224Decal DC-972 Safety Alert DecalsDecal DC-1229 Decal DC-1227Decal DC-1225 Decal DC-973 RegulationsDryer Control Panel Moisture Control Dryer Control Panel Featuring the 100 Series Control SystemUnload Switch Dryer Power Stop Switch Setting the Dry, Cool, Unload and Out of Grain Timers Monitoring Grain Temperatures, Plenum Temperature or Timers Safety Circuit Shut Down Messages Special FeaturesLoss of Flame Error Conditions Error Conditions Inspect the Metering Rolls Set Control SwitchesControl Power Switch Electrical PowerPower Start Button Fuel CheckMetering Roll Operation Fan SwitchHeater Test Fire Burner SafetyStaged Batch Check LP Gas Natural GasRef # Description Dryer Shut DownStopping Dryer Operation Filling the Dryer Continuous Flow OperationFull Start-Up Check Staged Batch Operation Fan Setting Heater Setting Fan Function Heater FunctionPNEG-552 100 Series Dryer Starting the Dryer Series Batch Timer SettingsAdjusting the Temperature Full Heat Continuous Flow Operation Moisture % Removed pts Speed Dry Time min Low High Adjusting the Moisture ControlInitial Moisture Full Heat Approximate Hours of Service per Year Range Suggested Lube Interval Seasonal Inspection and ServiceSuggested Lubricants Lubrication ProceduresAdditional Checks Insulation Class Consistency Type Grease Frame TypeRef # Description Clearance Holes Fan Propeller Removal and InstallationThreaded Bushing Holes Fan Blade Removal Fan Motor Removal and InstallationPosition of Fan Motor Heater Parts Removal and Installation Main Controls Metering Roll ServicingAs necessary. See F How to Determine a Metering Roll ProblemHow to Clear a Jammed Metering Roll Series Single Fan Wiring to Control Box Series Front Panel External Wiring Series Front Panel Internal Wiring Series Lower Back Panel Wiring Series External Wiring to Dryer Series Upper Control Box Wiring Series Main Power Wiring Series Control Schematic Series Control Schematic PNEG-552 100 Series Dryer Series 220 Volt 1 Phase Power Schematic Series 220VAC 3 Phase Power Schematic Series 440VAC 3 Phase Power Schematic Display shows Vapor High Temperature Problem Possible CausePress the dryer power start button Display shows Grain High Temperature Display shows Plenum High TemperaturePlenum High Temperature messages at Display shows Rear Discharge WarningTroubleshooting Wires connected together, the thermostat is faulty FAQs PNEG-552100 Series Dryer GSI Group Warranty