5. Dryer Pre-Start Checks

Metering Roll Operation

To check the metering roll operation, turn high speed knob clockwise. The metering roll speed should increase. Turning the knob counterclockwise will decrease the speed. Turn ON the MOISTURE CONTROL switch. If the Grain Temperature Setpoint is set above the outside temperature, the system will switch to Low Speed if working correctly. Make sure the drive chain tension is properly adjusted and all sections of the metering rolls rotate. Turn the unload switch OFF after these checks are complete. The bottom auger will continue to run for 30 seconds after the switch is turned OFF to allow for clean-out.

Figure 5B The Metering Roll Access Area

Fan Switch

Bump the FAN switch and observe the fan rotation. The fan should run counterclockwise. Sometimes on three phase models all motors on the dryer will run backwards. They can easily be reversed by interchanging two of three power supply wires. Reverse the two outside wires, L1 and L3 and leave the middle one in the same position.

NOTE: If the dryer is empty, the burner does not operate. The fans cannot create enough static pressure to engage the air switch. You will receive a “no airflow” message. To start the dryer when it is low on grain, the airflow switches must be turned OFF. Switching Dip Switch number eight (#8), on the back of the computer control board, to ON turns the Air Switch OFF.

Dip switch number eight (#8) must be turned back to the OFF position after this test is complete or no air testing will occur.

24

PNEG-552100 Series Dryer

Image 24
Contents Series Dryer PNEG-552100 Series Dryer Contents Table of Contents Safety Guidelines Dryer Operation Emergency StopSafety Precautions Use Caution in the Operation of this EquipmentDecal DC-1224 Decal DC-889Safety Alert Decals Decal DC-972Decal DC-1227 Decal DC-1225Decal DC-1229 Regulations Decal DC-973Dryer Control Panel Dryer Control Panel Featuring the 100 Series Control System Moisture ControlUnload Switch Dryer Power Stop Switch Setting the Dry, Cool, Unload and Out of Grain Timers Monitoring Grain Temperatures, Plenum Temperature or Timers Special Features Safety Circuit Shut Down MessagesLoss of Flame Error Conditions Error Conditions Set Control Switches Inspect the Metering RollsElectrical Power Control Power SwitchPower Start Button Fuel CheckFan Switch Metering Roll OperationBurner Safety Heater Test FireStaged Batch Check LP Gas Natural GasDryer Shut Down Stopping Dryer OperationRef # Description Continuous Flow Operation Full Start-Up CheckFilling the Dryer Fan Setting Heater Setting Fan Function Heater Function Staged Batch OperationPNEG-552 100 Series Dryer Series Batch Timer Settings Starting the DryerAdjusting the Temperature Full Heat Continuous Flow Operation Adjusting the Moisture Control Initial Moisture Full Heat ApproximateMoisture % Removed pts Speed Dry Time min Low High Seasonal Inspection and Service Hours of Service per Year Range Suggested Lube IntervalLubrication Procedures Suggested LubricantsAdditional Checks Insulation Class Consistency Type Grease Frame TypeRef # Description Fan Propeller Removal and Installation Threaded Bushing HolesClearance Holes Fan Motor Removal and Installation Fan Blade RemovalPosition of Fan Motor Heater Parts Removal and Installation Metering Roll Servicing Main ControlsHow to Determine a Metering Roll Problem As necessary. See FHow to Clear a Jammed Metering Roll Series Single Fan Wiring to Control Box Series Front Panel External Wiring Series Front Panel Internal Wiring Series Lower Back Panel Wiring Series External Wiring to Dryer Series Upper Control Box Wiring Series Main Power Wiring Series Control Schematic Series Control Schematic PNEG-552 100 Series Dryer Series 220 Volt 1 Phase Power Schematic Series 220VAC 3 Phase Power Schematic Series 440VAC 3 Phase Power Schematic Problem Possible Cause Press the dryer power start buttonDisplay shows Vapor High Temperature Display shows Plenum High Temperature Display shows Grain High TemperaturePlenum High Temperature messages at Display shows Rear Discharge WarningTroubleshooting Wires connected together, the thermostat is faulty FAQs PNEG-552100 Series Dryer GSI Group Warranty