5. Dryer Pre-Start Checks

Electrical Power

Turn ON the electrical power supply to the dryer. Set all circuit breakers to ON, including the safety disconnect handle mounted on front of the dryer’s power panel.

Control Power Switch

Turn the CONTROL POWER switch to ON. The switch light comes on. “GSI” and the software version will appear. At this point, the controller will lock out all other dryer functions and the dryer will perform its safety circuit check. If a fault is found, the cause will be displayed on the LCD. If all safeties are found safe, the controller will supply power to the electronic fuel shut off valve (if so equipped). Press the start button to initialize the computer.

Power Start Button

Push the dryer start button, and all the toggle switches on the control panel will be activated. This initializes the load, fan, burner, unload and metering rolls individually.

Fuel Check

If using LP gas, make sure the tank has plenty of fuel and that the TANK DOES NOT HAVE A PRESSURE REGULATOR MOUNTED TO IT. If using natural gas, make sure an adequate supply is available.

If using LP gas, slowly open the main fuel supply valve at the tank. If using natural gas, turn ON the valve along the supply line. Then, open the electronic shut off valve (Asco valve), if so equipped, or open the manual shut off valve on the dryer to allow fuel flow to the dryer. Inspect all gas lines and connections for possible leaks. ANY GAS LEAKS NEED TO BE FIXED IMMEDIATELY.

Load Auger

With the grain supply shut off, quickly bump the load auger switch to MANUAL and see if the load auger rotates clockwise, as viewed from the drive end, or counterclockwise if the dryer is a front load model. If the wet grain supply auxiliary is wired to the dryer it should also rotate in the correct direction at this time. Turn the load auger switch to the AUTO position. The top auger and wet grain supply auxiliary should run for one minute and then the dryer will shut down leaving the safety shut down message (out of grain) displayed. Press the dryer power stop button to reset the panel, then press the start button to resume operation.

1 Speed Operation

To check 1 Speed operation, place the unload switch in the 1 Speed setting. Turn the high speed metering roll dial up until the metering rolls start rotating. The bottom auger should rotate counterclockwise, as viewed from the drive end. The metering roll drive motor should rotate clockwise, as viewed from the drive end of the gear box. If the dry grain take away auxiliary is wired to the dryer, it should start and rotate in the proper direction.

PNEG-552100 Series Dryer

23

Image 23
Contents Series Dryer PNEG-552100 Series Dryer Contents Table of Contents Safety Guidelines Emergency Stop Dryer OperationUse Caution in the Operation of this Equipment Safety PrecautionsDecal DC-889 Decal DC-1224Decal DC-972 Safety Alert DecalsDecal DC-1229 Decal DC-1227Decal DC-1225 Decal DC-973 RegulationsDryer Control Panel Moisture Control Dryer Control Panel Featuring the 100 Series Control SystemUnload Switch Dryer Power Stop Switch Setting the Dry, Cool, Unload and Out of Grain Timers Monitoring Grain Temperatures, Plenum Temperature or Timers Safety Circuit Shut Down Messages Special FeaturesLoss of Flame Error Conditions Error Conditions Inspect the Metering Rolls Set Control SwitchesFuel Check Electrical PowerControl Power Switch Power Start ButtonMetering Roll Operation Fan SwitchLP Gas Natural Gas Burner SafetyHeater Test Fire Staged Batch CheckRef # Description Dryer Shut DownStopping Dryer Operation Filling the Dryer Continuous Flow OperationFull Start-Up Check Staged Batch Operation Fan Setting Heater Setting Fan Function Heater FunctionPNEG-552 100 Series Dryer Starting the Dryer Series Batch Timer SettingsAdjusting the Temperature Full Heat Continuous Flow Operation Moisture % Removed pts Speed Dry Time min Low High Adjusting the Moisture ControlInitial Moisture Full Heat Approximate Hours of Service per Year Range Suggested Lube Interval Seasonal Inspection and ServiceInsulation Class Consistency Type Grease Frame Type Lubrication ProceduresSuggested Lubricants Additional ChecksRef # Description Clearance Holes Fan Propeller Removal and InstallationThreaded Bushing Holes Fan Blade Removal Fan Motor Removal and InstallationPosition of Fan Motor Heater Parts Removal and Installation Main Controls Metering Roll ServicingAs necessary. See F How to Determine a Metering Roll ProblemHow to Clear a Jammed Metering Roll Series Single Fan Wiring to Control Box Series Front Panel External Wiring Series Front Panel Internal Wiring Series Lower Back Panel Wiring Series External Wiring to Dryer Series Upper Control Box Wiring Series Main Power Wiring Series Control Schematic Series Control Schematic PNEG-552 100 Series Dryer Series 220 Volt 1 Phase Power Schematic Series 220VAC 3 Phase Power Schematic Series 440VAC 3 Phase Power Schematic Display shows Vapor High Temperature Problem Possible CausePress the dryer power start button Display shows Rear Discharge Warning Display shows Plenum High TemperatureDisplay shows Grain High Temperature Plenum High Temperature messages atTroubleshooting Wires connected together, the thermostat is faulty FAQs PNEG-552100 Series Dryer GSI Group Warranty