Amana YKEHS01P manual Electrical Requirements U.S.A. Only

Page 7

Minimum installation spacing for cabinet installation

The dimensions shown are for the minimum spacing allowed.

For cabinet installation, with a door, minimum ventilation openings in the top of the cabinet are required.

7" (17.8 cm)

7" (17.8 cm)

9"

(22.9 cm)

0"

31¹ "

0"

0"

27"

0"

(0 cm)

(80.0 cm)

(0 cm) (0 cm)

(68.6 cm)

(0 cm)

Mobile home - Additional installation requirements

This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH.

Mobile home installations require:

Metal exhaust system hardware which is available for purchase from your dealer.

Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.

Electrical Requirements - U.S.A. Only

It is your responsibility

To contact a qualified electrical installer.

To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition and all local codes and ordinances.

The National Electric Code requires a 4-wire power supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.

A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269.

To supply the required 3 or 4 wire, single phase, 120/240-volt, 60-Hz., AC-only electrical supply (or 3 or 4 wire, 120/208-volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.

Do not use an extension cord.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

Electrical Connection

To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.

This dryer is manufactured ready to install with a 3-wire electrical supply connection. The green cabinet-grounding conductor is permanently connected to the neutral conductor (white wire) within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the green cabinet- grounding conductor must be removed from the external ground connector (green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the green cabinet-grounding conductor is secured under the neutral terminal (center or white wire) of the terminal block, the dryer cabinet is isolated from the neutral conductor.

If local codes do not permit the connection of a cabinet ground connector to the neutral wire, see “Optional 3-wire connection” section.

Use a 4-wire conductor cord when the dryer is installed in a mobile home or an area where local codes do not permit grounding through the neutral.

If using a power supply cord:

Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain:

A UL listed 30 amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.

A UL listed strain relief.

If your outlet looks like this:

4-wire receptacle (14-30R)

Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft (1.22 m) long, must have 4, 10-gauge solid copper wires and match a 4-wire receptacle of NEMA Type

14-30R. The ground wire (ground conductor) may be either green or bare. The neutral conductor must be identified by a white cover.

If your outlet looks like this:

3-wire receptacle (10-30R)

Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. The 3-wire power supply cord, at least 4 ft (1.22 m) long, must have 3, 10-gauge solid copper wires and match a 3-wire receptacle of NEMA Type 10-30R.

7

Image 7
Contents Secadora Eléctrica DE Carga Frontal FRONT-LOADING Electric DryerSécheuse Électrique À Chargement Lavant Índice Table of ContentsTable DES Matières Sécurité DE LA Sécheuse Instructions DinstallationYour safety and the safety of others are very important Dryer SafetyLocation Requirements Installation InstructionsTools and Parts OptionsCloset installation Dryer only Installation clearancesDryer Dimensions Custom undercounter installation Dryer onlyElectrical Requirements U.S.A. Only Electrical Requirements Canada Only If connecting by direct wireElectrical Connection U.S.A. Only Wire connection Power supply cord Wire connection Direct wire Optional 3-wire connection Plan Vent System Typical exhaust installationsOptional exhaust installations Venting RequirementsAngled hood style shown following is acceptable Alternate installations for close clearancesSpecial provisions for mobile home installations Determine Vent LengthConnect Vent Install Vent SystemInstall Leveling Legs Level DryerReverse the hinge and hinge bracket Reinstalling the doorClose the door and check that it latches securely Complete InstallationIf the dryer will not start, check the following Starting Your Dryer Dryer USETo use an Automatic Cycle Control Locked Pausing or RestartingStopping Your Dryer LoadingCycles Status LightsAdditional Features Drying Rack Cleaning the Dryer LocationCycle End Signal Dryer CareVacation and Moving Care Cleaning the Lint ScreenCleaning the Dryer Interior Removing Accumulated LintChanging the Drum Light TroubleshootingU.S.A Assistance or ServiceCanada KitchenAid will not pay for Kitchenaid Dryer WarrantySu seguridad y la seguridad de los demás es muy importante Seguridad DE LA SecadoraRequisitos de ubicación Instrucciones DE InstalaciónHerramientas y piezas OpcionesEspacios para la instalación Dimensiones de la secadoraInstalación en un clóset Sólo para la secadora Usted es responsable de Requisitos eléctricos Sólo en EE. UUEspacio mínimo para la instalación en un armario Las instalaciones en casas rodantes necesitanSi el contacto de pared luce como éste Si emplea un cable de suministro eléctricoSi hace la conexión con cableado directo Cable de suministro eléctrico Conexión eléctrica Sólo en EE. UUCableado directo Conectar con Conexión de 4 hilos Cordón de suministro de corrienteConexión de 4 hilos Cable directo Conexión de 3 hilos Cordón de suministro eléctricoConexión opcional de 3 hilos Conexión de 3 hilos Cable directoInstalaciones opcionales de escape Requisitos de ventilaciónPlanificación del sistema de ventilación Instalaciones típicas de escapeCálculo de la longitud del ducto de escape Instalaciones alternas para espacios limitadosInstalación de las patas niveladoras Instalación del sistema de ventilaciónCómo quitar la puerta Nivelación de la secadoraConexión del ducto de escape Cómo invertir el cierre de la puertaLea Uso de la secadora Complete la instalaciónCómo volver a instalar la puerta Cierre la puerta y fíjese que se cierre con seguridadDirija el selector hacia un ciclo Automático USO DE LA SecadoraPuesta en marcha de la secadora Para usar un ciclo AutomáticoControl bloqueado Detención de la marcha De la secadoraCómo cargar Pausa o reanudación de la marchaCiclos Luces de estadoCaracterísticas adicionales Cuando use Sólo aire Alarma de Fin de Ciclo Cycle End SignalEstante de secado Sólo aire Air OnlyLimpieza de cada carga Cuidado DE LA SecadoraLimpieza del lugar donde está La secadora Limpieza del filtro de pelusaCambio de la luz del tambor Limpieza del interior de la secadoraEliminación de pelusa acumulada Cuidado para las vacaciones y La mudanzaPelusa en la ropa Solución DE ProblemasLa ropa no se está secando bien Sonidos rarosAyuda O Servicio Técnico KitchenAid no pagará por Garantía DE LA Secadora KitchenaidVotre sécurité et celle des autres est très importante Sécurité DE LA SécheuseEmplacement d’installation Instructions DinstallationOutillage et pièces nécessaires Dimensions de la sécheuse Espacements dinstallationInstallation dans un placard Sécheuse seulement Spécifications électriques Canada seulement Linstallation dans une maison mobile exigeNe pas utiliser de cordon de rallonge Instructions DE Liaison À LA Terre Exigences concernant l’évacuationPlanification du système dévacuation Installations typiques d’évacuationInstallations d’évacuation facultatives Autres installations où le dégagement est réduitDétermination de la longueur du conduit Installation du conduit d’évacuationLe clapet incliné illustré ci-dessous est acceptable Inversion de louverture de la porte Installation des pieds de nivellementMise àniveau de la sécheuse Conduit d’évacuationInverser la charnière et son support Réinstallation de la porteFermer la porte et vérifier qu’elle s’enclenche solidement Achever l’installationSi la sécheuse ne démarre pas, vérifier ce qui suit Mise en marche de la sécheuse Utilisation DE LA SécheuseUtilisation dun programme automatique Chargement Verrouillage des commandesArrêt de la sécheuse Arrêt ou remise en marcheTémoins lumineux Conseils pour le séchage et les ProgrammesHeavy Duty tissus robustes Control Locked verrouillage des commandesCaractéristique Extra Care ultra soin Témoins lumineuxCaractéristiques supplémentaires Grille de séchage Nettoyage de l’intérieur de la sécheuse Nettoyage de lemplacement de La sécheuseEntretien DE LA Sécheuse Nettoyage du filtre àcharpieRetrait de la charpie accumulée DépannageChangement de l’ampoule d’éclairage Du tambour Présence de taches sur les vêtements ou décoloration La sécheuse ne fonctionne pasSons inhabituels Charpie sur la chargePour plus d’assistance Assistance OU ServicePour pièces, accessoires et service Si vous avez besoin de pièces de rechangeKitchenAid Canada ne paiera pas pour Garantie DE LA Sécheuse KitchenaidAll rights reserved 8557328