American Dryer Corp AD-310 Phase 7 SPECIFICATIONS/DIMENSIONS Component Identification

Page 10

SECTION II

SPECIFICATIONS/DIMENSIONS

AND COMPONENT IDENTIFICATION

A. SPECIFICATIONS (GAS AND STEAM)

MAXIMUM CAPACITY (DRY WEIGHT)

310 lbs

 

 

141 kg

 

 

 

 

 

 

 

BASKET (TUMBLER) DIAMETER

62-1/2”

 

 

158.75 cm

 

 

 

 

 

 

 

BASKET (TUMBLER) DEPTH

60”

 

 

152.4 cm

 

 

 

 

 

 

 

BASKET (TUMBLER) VOLUME

106.5 cu. ft.

 

 

3.02 cu. m.

 

 

 

 

 

 

 

 

DRIVE MOTOR

 

5 HP

 

 

3.73 kw

 

 

 

 

 

 

 

DOOR OPENING (DIAMETER)

36-3/4” w x 43” h

 

 

93.3 cm x 109.2 cm

 

 

 

 

 

 

 

DOOR STILL HEIGHT - LEVEL

36-1/2”

 

 

92.71 cm

 

 

 

 

 

 

 

 

COMPRESSED AIR

 

80 PSI

 

 

5.51 bars

 

 

 

 

 

 

COMPRESSED AIR CONNECTION

 

3/8” F.P.T.

 

 

 

 

 

 

 

 

VOLTAGE AVAILABLE

208-600v

3, 4w 50/60 Hz

 

 

 

 

 

 

 

 

Gas*

BLOWER MOTOR

 

15 HP

 

 

11.25 kw

 

 

 

 

 

 

 

HEAT INPUT

 

1,125,000 btu/hr

 

 

283,500 kcal/hr

 

 

 

 

 

 

 

 

 

 

 

 

APPROX. WEIGHT (UNCRATED)

5,100 lbs

 

 

2,314 kg

 

 

 

 

 

 

 

 

 

AIRFLOW

 

6,500 cfm

 

 

184.1 cmm

 

 

 

 

 

 

 

 

INLET PIPE SIZE

 

 

 

1-1/2”

 

 

 

 

 

 

 

 

VOLTAGE AVAILABLE

208-600v

3, 4w 50/60 Hz

 

 

 

 

 

 

 

 

 

BLOWER MOTOR

 

25 HP

 

 

18.64 kw

Steam*

 

 

 

 

 

 

APPROX. WEIGHT (UNCRATED)

5,600 lbs

 

 

2,540 kg

 

 

 

 

 

 

 

AIRFLOW

 

8,500 cfm

 

 

240.7 cmm

 

 

 

 

 

 

 

 

 

 

 

 

 

STEAM CONSUMPTION

BOILER HP

 

 

 

 

NORMAL LOAD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1,153 lbs/hr

 

524 kg/hr

55

 

 

 

 

 

 

 

 

 

 

 

OPERATING STEAM PRESSURE

STEAM SUPPLY

 

 

STEAM RETURN

 

 

 

 

 

 

 

 

 

125 PSI max

 

8.62 bars

2”

 

 

2”

 

 

 

 

 

 

 

Shaded areas are stated in metric equivalents

 

 

 

 

*Dryers must be provided with a clean, dry, and regulated 80 PSI +/- 10 PSI (5.51 bars +/- 0.68 bars) air supply (equivalent volume = 9 cfh [0.25 cmh]).

NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation.

6

Image 10
Contents AD-310 Phase Retain This Manual In a Safe Place For Future Reference Foryour Safety Page Table of Contents Section Burner and Basket TUMBLER/LINT Chamber Manual Reset Important Information Receiving and HandlingSafety Precautions What to do if YOU Smell GASStandards SPECIFICATIONS/DIMENSIONS Component Identification Specifications GAS and SteamDimensions and Component Location NON-TILT Steam Model Installation Procedures Reassembly of DryerPage Lift the basket tumbler section onto the base Page Reassembly Instructions For Non-Tilt Steam Dryers Location Requirements Fresh AIR Supply Requirements Exhaust Requirements Page Page Page Page Page Compressed AIR Supply System Page Page Electrical Information Electrical RequirementsGas Non-Tilt Steam Non-Tilt Page GAS Information Type of GAS Page Water Supply Connection for Optional Sprinkler System Operating Steam Pressure Steam InformationPage Compressed Air Supply Air Pressure Page Steam Damper Air Piston Flow Control Operation Adjustment Preoperational Tests Natural Gas Inches 8.7 mb water column Liquid Propane L.P Preparation for OPERATION/START-UP Basket CoatingShut Down Instructions Service SERVICE/PARTS InformationParts Warranty Warranty InformationReturning Warranty Cards Returning Warranty PartsPage Cleaning Routine MaintenanceSuggested Cleaning Schedule Monthly Adjustments LubricationBasket Tumbler Drive System Component System DescriptionsBasket Tumbler Drive System Basket Tumbler Safety DevicesAIR Blower Drive System Page Steam Damper Actuator System P O R T a N T Phase 7 Steam Models only Data Label Information Data LabelSerial Number Procedure for Functional Check Replacement Components Page Phase 7 OPL System Diagnostics Diagnostic L.E.D. Display Fault MessagesPage O Board Input and Output L.E.D. Indicators Inputs RED Outputs Green RHE PGR1 Green L.E.D OCL5 Green L.E.D Troubleshooting No DisplayDrive motor is not operating does not start Impellor fan motor is not operating does not start Page Page Dryer operates but is taking too long to dry Excessive noise and vibration Tilt to unload Optional Sprinkler System Components Optional Sprinkler Circuit ComponentsSprinkler and Main Power Connections Sprinkler Option Temperature Controller Settings Page ADC 01/04/00-20 05/07/01-20
Related manuals
Manual 116 pages 19.79 Kb