8.

RDRO – (RED L.E.D.)

This L.E.D. will indicate the status of the Rear Doors. If the doors are open,

 

 

then the L.E.D. is ON.

9.

FAN – (RED L.E.D.)

This L.E.D. will indicate the status of the Blower Fan. If the fan is on, then the

 

 

L.E.D. is ON.

10.

RBHL – (RED L.E.D.)

This L.E.D. will indicate the status of the Rear Burner Hi-Limit Disk. If the

 

 

disk is closed (Temperature below 330º F [166º C]), then the L.E.D. is ON.

11.

R_SS – (RED L.E.D.)

This L.E.D. will indicate the status of the Rear Sail Switch. If the switch is

 

 

closed, then the L.E.D. is ON.

12.

FBHL – (RED L.E.D.)

This L.E.D. will indicate the status of the Front Burner Hi-Limit Disk. If the

 

 

disk is closed (Temperature below 330º F [166º C]), then the L.E.D. is ON.

13.

F_SS – (RED L.E.D.)

This L.E.D. will indicate the status of the Front Sail Switch. If the switch is

 

 

closed, then the L.E.D. is ON.

14.

EXHL – (RED L.E.D.)

This L.E.D. will indicate the status of the Exhaust Hi-Limit Disk. If the disk is

 

 

closed (Temperature below 225º F [107º C]), then the L.E.D. is ON.

15.

DRY – (RED L.E.D.)

This L.E.D. will indicate the status of the Programmable Logic Controller (PLC).

 

 

If the mechanical functions of the dryer have been set to the DRY position, the

 

 

PLC will send a signal to the Phase 7 board. This signal will indicate that ALL

 

 

the doors are closed and the dryer is level. When these conditions are met, then

 

 

the L.E.D. is ON.

16.

LINT – (RED L.E.D.)

This L.E.D. will indicate the status of the Lint Drawer. If the drawer is closed,

 

 

then the L.E.D. is ON.

17.

R_HE

Supply power for rear heat output (optional).

18.

F_HE

Supply power for front heat output.

19.

24VM – (RED L.E.D.)

Control voltage at the spare inputs.

20.

FVLV – (RED L.E.D.)

This L.E.D. will indicate the status of the Front Gas Valve. If the Front Gas

 

 

Valve is open (ON), then the L.E.D. is ON.

21.

RVLV – (RED L.E.D.)

This L.E.D. will indicate the status of the Rear Gas Valve. If the Rear Gas

 

 

Valve is open (ON), then the L.E.D. is ON.

22.

SPR1 – (RED L.E.D.)

This is for a spare input to be used with programmable outputs.

23.

SPR2 – (RED L.E.D.)

This is for a spare input to be used with programmable outputs.

24.

SPR3 – (RED L.E.D.)

This is for a spare input to be used with programmable outputs.

25.

SPR4 – (RED L.E.D.)

This is for a spare input to be used with programmable outputs.

26.

SPR5 – (RED L.E.D.)

This is for a spare input to be used with programmable outputs.

27.

+24 – (RED L.E.D.)

This L.E.D. will indicate the board voltage that is protected by Fuse #2.

28.

24IN – (RED L.E.D.)

This L.E.D. will indicate 24 VAC to the board.

29.

MCR+ - (RED L.E.D.)

This L.E.D. will indicate the status of the Control Voltage. If the Power On

 

 

button is pressed (Green Button Light is On), then the L.E.D. is ON.

62

Image 66
Contents AD-310 Phase Retain This Manual In a Safe Place For Future Reference Foryour Safety Page Table of Contents Section Burner and Basket TUMBLER/LINT Chamber Manual Reset Important Information Receiving and HandlingSafety Precautions What to do if YOU Smell GASStandards SPECIFICATIONS/DIMENSIONS Component Identification Specifications GAS and SteamDimensions and Component Location NON-TILT Steam Model Installation Procedures Reassembly of DryerPage Lift the basket tumbler section onto the base Page Reassembly Instructions For Non-Tilt Steam Dryers Location Requirements Fresh AIR Supply Requirements Exhaust Requirements Page Page Page Page Page Compressed AIR Supply System Page Page Electrical Information Electrical RequirementsGas Non-Tilt Steam Non-Tilt Page GAS Information Type of GAS Page Water Supply Connection for Optional Sprinkler System Operating Steam Pressure Steam InformationPage Compressed Air Supply Air Pressure Page Steam Damper Air Piston Flow Control Operation Adjustment Preoperational Tests Natural Gas Inches 8.7 mb water column Liquid Propane L.P Preparation for OPERATION/START-UP Basket CoatingShut Down Instructions SERVICE/PARTS Information ServiceParts Warranty Warranty InformationReturning Warranty Cards Returning Warranty PartsPage Routine Maintenance CleaningSuggested Cleaning Schedule Monthly Adjustments LubricationComponent System Descriptions Basket Tumbler Drive SystemBasket Tumbler Drive System Safety Devices Basket TumblerAIR Blower Drive System Page Steam Damper Actuator System P O R T a N T Phase 7 Steam Models only Data Label Information Data LabelSerial Number Procedure for Functional Check Replacement Components Page Phase 7 OPL System Diagnostics Diagnostic L.E.D. Display Fault MessagesPage O Board Input and Output L.E.D. Indicators Inputs RED Outputs Green RHE PGR1 Green L.E.D OCL5 Green L.E.D Troubleshooting No DisplayDrive motor is not operating does not start Impellor fan motor is not operating does not start Page Page Dryer operates but is taking too long to dry Excessive noise and vibration Tilt to unload Optional Sprinkler System Components Optional Sprinkler Circuit ComponentsSprinkler and Main Power Connections Sprinkler Option Temperature Controller Settings Page ADC 01/04/00-20 05/07/01-20