American Dryer Corp AD-310 Phase 7 installation manual Inputs RED Outputs Green

Page 65

INPUTS: (RED)

OUTPUTS: (GREEN)

1.

FDRC - Front Door Closed

1.

R_HEAT - Rear Heat

2.

FDRO - Front Door Open

2.

AUDIO ALERT - Horn On

3.

TBOL - Basket (Tumbler) Overload

3.

FWD - Basket (Tumbler) Forward

4.

FNOL - Fan Overload

4.

REV - Basket (Tumbler) Reverse

5.

RDWN - Rear Down

5.

AIR JET - Air Jet On

6.

FDWN - Front Down

6.

FAN - Blower Fan On

7.

RDRC - Rear Door Closed

7.

F_HEAT - Front Heat

8.

RDRO - Rear Door Open

8.

PRG1 - Programmable Output #1

9.

FAN - Blower Fan On

9.

PRG2 - Programmable Output #2

10.

RBHL - Rear Burner High Limit

10.

PRG3 - Programmable Output #3

11

R_SS - Rear Sail Switch

11.

PRG4 - Programmable Output #4

12.

FBHL - Front Burner High Limit

12.

OCL1 - Open Collector Output #1

13.

F_SS - Front Sail Switch

13.

OCL2 - Open Collector Output #2

14.

EXHL - Exhaust High Limit

14.

OCL3 - Open Collector Output #3

15.

DRY - Dry Enable Bit

15.

OCL4 - Open Collector Output #4

16.

LINT - Lint Drawer

16.

OCL5 - Open Collector Output #5

17.

R_HE - Rear Heat Enable

17.

OCL6 - Open Collector Output #6

18.

F_HE - Front Heat Enable

18.

OCL7 - Open Collector Output #7

19.

24VIN - Control Voltage 24 Volts AC

19.

OCL8 - Open Collector Output #8

20.

SPR5 - Spare Input #5

20.

EOC - End Of Cycle Light

21.SPR4 - Spare Input #4

22.SPR3 - Spare Input #3

23.SPR2 - Spare Input #2

24.SPR1 - Spare Input #1

25.RVLV - Rear Gas Valve

26.FVLV - Front Gas Valve

27.24IN - Board 24 Volt AC

28.+5V - Regulated Voltage

29.Model - Communication

Input/Output (I/O) Board Input Description (“Red” light emitting diode [L.E.D.])

1.

FDRC – (RED L.E.D.)

This L.E.D. will indicate the status of the Front Doors. If the doors are closed,

 

 

then the L.E.D. is ON.

2.

FDRO – (RED L.E.D.)

This L.E.D. will indicate the status of the Front Doors. If the doors are open,

 

 

then the L.E.D. is ON.

3.

TBOL – (RED L.E.D.)

This L.E.D. will indicate the status of the Basket (tumbler) Overload Contact.

 

 

If the contact is closed, then the L.E.D. is ON. If it faults open, then the L.E.D.

 

 

is OFF.

4.

FNOL – (RED L.E.D.)

This L.E.D. will indicate the status of the Fan Overload Contact. If the contact

 

 

is closed, then the L.E.D. is ON. If it faults open, then the L.E.D. is OFF.

5.

RDWN – (RED L.E.D.)

This L.E.D. will indicate the status of the Rear Tilt. If the rear of the dryer is

 

 

down, then the L.E.D. is ON (optional).

6.

FDWN – (RED L.E.D.)

This L.E.D. will indicate the status of the Front Tilt. If the front of the dryer is

 

 

down, then the L.E.D. is ON (optional).

7.

RDRC – (RED L.E.D.)

This L.E.D. will indicate the status of the Rear Doors. If the doors are closed,

 

 

then the L.E.D. is ON.

61

Image 65
Contents AD-310 Phase Retain This Manual In a Safe Place For Future Reference Foryour Safety Page Table of Contents Section Burner and Basket TUMBLER/LINT Chamber Manual Reset Receiving and Handling Important InformationWhat to do if YOU Smell GAS Safety PrecautionsStandards Specifications GAS and Steam SPECIFICATIONS/DIMENSIONS Component IdentificationDimensions and Component Location NON-TILT Steam Model Reassembly of Dryer Installation ProceduresPage Lift the basket tumbler section onto the base Page Reassembly Instructions For Non-Tilt Steam Dryers Location Requirements Fresh AIR Supply Requirements Exhaust Requirements Page Page Page Page Page Compressed AIR Supply System Page Page Electrical Requirements Electrical InformationGas Non-Tilt Steam Non-Tilt Page GAS Information Type of GAS Page Water Supply Connection for Optional Sprinkler System Steam Information Operating Steam PressurePage Compressed Air Supply Air Pressure Page Steam Damper Air Piston Flow Control Operation Adjustment Preoperational Tests Natural Gas Inches 8.7 mb water column Liquid Propane L.P Basket Coating Preparation for OPERATION/START-UPShut Down Instructions Parts SERVICE/PARTS InformationService Returning Warranty Cards Warranty InformationWarranty Returning Warranty PartsPage Suggested Cleaning Schedule Routine MaintenanceCleaning Monthly Lubrication AdjustmentsBasket Tumbler Drive System Component System DescriptionsBasket Tumbler Drive System AIR Blower Drive System Safety DevicesBasket Tumbler Page Steam Damper Actuator System P O R T a N T Phase 7 Steam Models only Data Label Data Label InformationSerial Number Procedure for Functional Check Replacement Components Page Diagnostic L.E.D. Display Fault Messages Phase 7 OPL System DiagnosticsPage O Board Input and Output L.E.D. Indicators Inputs RED Outputs Green RHE PGR1 Green L.E.D OCL5 Green L.E.D No Display TroubleshootingDrive motor is not operating does not start Impellor fan motor is not operating does not start Page Page Dryer operates but is taking too long to dry Excessive noise and vibration Tilt to unload Optional Sprinkler Circuit Components Optional Sprinkler System ComponentsSprinkler and Main Power Connections Sprinkler Option Temperature Controller Settings Page ADC 01/04/00-20 05/07/01-20