American Dryer Corp AD-310 Phase 7 installation manual PGR1 Green L.E.D

Page 67

Input/Output (I/O) Board Output Description (“Green” light emitting diode [L.E.D.])

1.

R_HEAT – (GREEN L.E.D.)

This L.E.D. will indicate the status of the Rear Heat output. If the request

 

 

to turn on the Rear Burner is made, then the L.E.D. is ON.

2.

ALERT – (GREEN L.E.D.)

This L.E.D. will indicate the status of the Horn output. If the request to

 

 

turn on the Horn is made, then the L.E.D. is ON.

3.

FWD – (GREEN L.E.D.)

This L.E.D. will indicate the status of the Basket (tumbler) Forward direction

 

 

output. If the request to tumble the drum in the Forward direction is made,

 

 

then the L.E.D. is ON.

4.

REV – (GREEN L.E.D.)

This L.E.D. will indicate the status of the Basket (tumbler) Reverse direction

 

 

output. If the request to tumble the drum in the Reverse direction is made,

 

 

then the L.E.D. is ON.

5.

AIR JET – (GREEN L.E.D.)

This L.E.D. will indicate the status of the Air Jet output. If the request to

 

 

turn on the Air Jet is made, then the L.E.D. is ON.

6.

FAN – (GREEN L.E.D.)

This L.E.D. will indicate the status of the Fan output. If the request to turn

 

 

on the Fan (blower) is made, then the L.E.D. is ON.

7.

F_HEAT – (GREEN L.E.D.)

This L.E.D. will indicate the status of the Front Heat output. If the request

 

 

to turn on the Front Burner is made, then the L.E.D. is ON.

8.

PGR1 – (GREEN L.E.D.)

This is for a spare output to be programmed.

9.

PGR2 – (GREEN L.E.D.)

This is for a spare output to be programmed.

10.

PGR3 – (GREEN L.E.D.)

This is for a spare output to be programmed.

11.

PGR4 – (GREEN L.E.D.)

This is for a spare output to be programmed.

12.

OCL1 – (GREEN L.E.D.)

This L.E.D. will indicate the status of the Open Collector #1 output. If the

 

 

request to turn on the Open Collector #1 is made, then the L.E.D. is ON.

 

 

(Programmable and Defaulted to Front Door Open.)

13.

OCL2 – (GREEN L.E.D.)

This L.E.D. will indicate the status of the Open Collector #2 output. If the

 

 

request to turn on the Open Collector #2 is made, then the L.E.D. is ON.

 

 

(Programmable and Defaulted to Front Door Closed.)

14.

OCL3 – (GREEN L.E.D.)

This L.E.D. will indicate the status of the Open Collector #3 output. If the

 

 

request to turn on the Open Collector #3 is made, then the L.E.D. is ON.

 

 

(Programmable and Defaulted to Lint Drawer.)

15.

OCL4 – (GREEN L.E.D.)

This L.E.D. will indicate the status of the Open Collector #4 output. If the

 

 

request to turn on the Open Collector #4 is made, then the L.E.D. is ON.

 

 

(Programmable and Defaulted to Front Down.)

63

Image 67
Contents AD-310 Phase Retain This Manual In a Safe Place For Future Reference Foryour Safety Page Table of Contents Section Burner and Basket TUMBLER/LINT Chamber Manual Reset Receiving and Handling Important InformationWhat to do if YOU Smell GAS Safety PrecautionsStandards Specifications GAS and Steam SPECIFICATIONS/DIMENSIONS Component IdentificationDimensions and Component Location NON-TILT Steam Model Reassembly of Dryer Installation ProceduresPage Lift the basket tumbler section onto the base Page Reassembly Instructions For Non-Tilt Steam Dryers Location Requirements Fresh AIR Supply Requirements Exhaust Requirements Page Page Page Page Page Compressed AIR Supply System Page Page Electrical Requirements Electrical InformationGas Non-Tilt Steam Non-Tilt Page GAS Information Type of GAS Page Water Supply Connection for Optional Sprinkler System Steam Information Operating Steam PressurePage Compressed Air Supply Air Pressure Page Steam Damper Air Piston Flow Control Operation Adjustment Preoperational Tests Natural Gas Inches 8.7 mb water column Liquid Propane L.P Basket Coating Preparation for OPERATION/START-UPShut Down Instructions Service SERVICE/PARTS InformationParts Returning Warranty Parts Warranty InformationReturning Warranty Cards WarrantyPage Cleaning Routine MaintenanceSuggested Cleaning Schedule Monthly Lubrication AdjustmentsBasket Tumbler Drive System Component System DescriptionsBasket Tumbler Drive System Basket Tumbler Safety DevicesAIR Blower Drive System Page Steam Damper Actuator System P O R T a N T Phase 7 Steam Models only Data Label Data Label InformationSerial Number Procedure for Functional Check Replacement Components Page Diagnostic L.E.D. Display Fault Messages Phase 7 OPL System DiagnosticsPage O Board Input and Output L.E.D. Indicators Inputs RED Outputs Green RHE PGR1 Green L.E.D OCL5 Green L.E.D No Display TroubleshootingDrive motor is not operating does not start Impellor fan motor is not operating does not start Page Page Dryer operates but is taking too long to dry Excessive noise and vibration Tilt to unload Optional Sprinkler Circuit Components Optional Sprinkler System ComponentsSprinkler and Main Power Connections Sprinkler Option Temperature Controller Settings Page ADC 01/04/00-20 05/07/01-20