310 (Steam) Non-Tilt
25 HP Blower Motor/5 HP Drive Motor
IMPORTANT: 208 VAC and 230 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTES: A.
B.
C.
Fuse ratings are dual element, time delay, current limiting, class RK1 or RK5 ONLY. Circuit breakers are thermal/magnetic (industrial) motor curve type ONLY. For others, calculate/ verify correct breaker size according to appliance amp draw rating and type of breaker used.
Circuit breakers for
SERVICE | PHASE | WIRE | APPROX. | FUSING | CIRCUIT | |
Dual Element | ||||||
VOLTAGE | SERVICE | AMP DRAW | BREAKER | |||
| Time Delay | |||||
|
|
|
|
| ||
208 | 3ø | 3/4 | 81 | 100 | 110 | |
|
|
|
|
|
| |
230 | 3ø | 3 | 72 | 100 | 110 | |
|
|
|
|
|
| |
380 | 3ø | 3/4 | 45 | 60 | 90 | |
416 | 3ø | 3/4 | 40 | 60 | 80 | |
|
|
|
|
|
| |
460/480 | 3ø | 3/4 | 40 | 60 | 80 | |
|
|
|
|
|
|
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is affixed to the right electrical control panel.
WARNING: 208 VAC and 230 VAC ARE NOT THE SAME. Any damage done to dryer components due to improper voltage connections will automatically VOID THE WARRANTY.
NOTE: ADC reserves the right to make any changes in specifications at any time without notice or obligation.
27