American Dryer Corp AD-310 Phase 7 Dryer operates but is taking too long to dry

Page 74

2)Failure in drive motor circuit.

b.Faulty rotation sensor.

c.Broken wire or connection between rotation sensor and microprocessor controller (computer) display board.

d.Failure in rotational sensor circuit, magnet missing, or gap too large.

e.Basket (tumbler) rotation below 12 RPMS.

P.Microprocessor controller (computer) reads “Exhaust High Temp Fault”...

1.Possible overheating condition...microprocessor controller (computer) display board has sensed a temperature, which has exceeded 225º F (107º C).

Exhaust High Temp Fault will display until the stop key has been passed. A cycle cannot be started until the temperature is below 220º F (104º C).

Q.Dryer operates but is taking too long to dry...

1.Exhaust ductwork run is too long or is undersized...back pressure cannot exceed 0.3 inches (0.74 mb) water column (W.C.).

2.Restriction in ductwork...check duct from the dryer ALL the way to the outdoors.

3.Low or inconsistent gas pressure (for gas models only).

4.Insufficient make-up air.

5.Poor air and gas mixture at burner - yellow or poor flame pattern...adjust gas burner air adjustment shutters (for gas models only).

6.Lint drawer or screen is not being cleaned on a regular basis or often enough.

7.Extractors (washers) are not performing properly.

8.Sail switch is fluttering...restriction in exhaust (for gas models only).

9.Failed microprocessor controller (computer)...temperature calibration is inaccurate.

10.Failed microprocessor temperature sensor...calibration is inaccurate.

11.Failed burner hi-limit (for gas models only).

12.Failed 225º F (107º C) manual reset hi-limit (thermostat).

13.Steam damper system is not functioning properly (for steam models only)...

a.Steam damper sticking closed.

b.Leak in pneumatic system.

70

Image 74
Contents AD-310 Phase Retain This Manual In a Safe Place For Future Reference Foryour Safety Page Table of Contents Section Burner and Basket TUMBLER/LINT Chamber Manual Reset Important Information Receiving and HandlingSafety Precautions What to do if YOU Smell GASStandards SPECIFICATIONS/DIMENSIONS Component Identification Specifications GAS and SteamDimensions and Component Location NON-TILT Steam Model Installation Procedures Reassembly of DryerPage Lift the basket tumbler section onto the base Page Reassembly Instructions For Non-Tilt Steam Dryers Location Requirements Fresh AIR Supply Requirements Exhaust Requirements Page Page Page Page Page Compressed AIR Supply System Page Page Electrical Information Electrical RequirementsGas Non-Tilt Steam Non-Tilt Page GAS Information Type of GAS Page Water Supply Connection for Optional Sprinkler System Operating Steam Pressure Steam InformationPage Compressed Air Supply Air Pressure Page Steam Damper Air Piston Flow Control Operation Adjustment Preoperational Tests Natural Gas Inches 8.7 mb water column Liquid Propane L.P Preparation for OPERATION/START-UP Basket CoatingShut Down Instructions Parts SERVICE/PARTS InformationService Warranty Warranty InformationReturning Warranty Cards Returning Warranty PartsPage Suggested Cleaning Schedule Routine MaintenanceCleaning Monthly Adjustments LubricationBasket Tumbler Drive System Component System DescriptionsBasket Tumbler Drive System AIR Blower Drive System Safety DevicesBasket Tumbler Page Steam Damper Actuator System P O R T a N T Phase 7 Steam Models only Data Label Information Data LabelSerial Number Procedure for Functional Check Replacement Components Page Phase 7 OPL System Diagnostics Diagnostic L.E.D. Display Fault MessagesPage O Board Input and Output L.E.D. Indicators Inputs RED Outputs Green RHE PGR1 Green L.E.D OCL5 Green L.E.D Troubleshooting No DisplayDrive motor is not operating does not start Impellor fan motor is not operating does not start Page Page Dryer operates but is taking too long to dry Excessive noise and vibration Tilt to unload Optional Sprinkler System Components Optional Sprinkler Circuit ComponentsSprinkler and Main Power Connections Sprinkler Option Temperature Controller Settings Page ADC 01/04/00-20 05/07/01-20
Related manuals