CALL FOR SERVICE - Indicates a board failure.
FRONT DOOR NOT CLOSED - A front door is open when it should be closed.
REAR DOOR NOT CLOSED - A rear door is open when it should be closed.
CHECK CONTROL POWER - Indicates control power is off.
EXHAUST HIGH TEMP FAULT - Indicates the temperature in the basket (tumbler) is above 225º F (107º C). LINT DRAWER OPEN - Indicates the lint drawer is open and needs to be closed.
DRY ENABLE FAULT - Indicates the dryer is not level and ALL doors are closed. Not ready to start drying. FRONT NOT DOWN - dryer is tilted back.
REAR NOT DOWN - dryer is tilted forward.
TUMBLER OVERLOAD FAULT - Indicates the basket (tumbler) overload has tripped open. FAN OVERLOAD FAULT - Indicates the fan overload has tripped open.
EXHAUST
FAN CONTACTOR FAULT - The fan contactor was not pulled in.
FRONT BURNER
FRONT BURNER VALVE FAULT - Indicates front gas valve is not working or no gas is turned on or flameout. REAR BURNER VALVE FAULT - Indicates rear gas valve is not working or no gas is turned on or flameout. FRONT BURNER IGNITION CONTROL FAULT - Front ignition module is not working or failure to ignite.
REAR BURNER IGNITION CONTROL FAULT - Rear ignition module is not working or failure to ignite. ROTATION FAULT - Indicates the basket (tumbler) is not rotating.
BAD PROBE - Indicates the temperature probe is open or shorted.
LOW VOLTAGE FAULT - Indicates power has dropped below the operating values and will shut down.
59