2.Electrical Service Specifications
310 (Gas) Non-Tilt
15 HP Blower/5 HP Drive Motor
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC and 230 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTES: | A. | Fuse ratings are dual element, time delay, current limiting, class RK1 or RK5 ONLY. |
| B. | Circuit breakers are thermal/magnetic (industrial) motor curve type ONLY. For others, |
| calculate/ verify correct breaker size according to appliance amp draw rating and type of | |
|
| breaker used. |
| C. | Circuit breakers for |
SERVICE | PHASE | WIRE | APPROX. | FUSING | CIRCUIT | |
Dual Element | ||||||
VOLTAGE | SERVICE | AMP DRAW | BREAKER | |||
| Time Delay | |||||
|
|
|
|
| ||
208 | 3ø | 3/4 | 57 | 80 | 90 | |
|
|
|
|
|
| |
230 | 3ø | 3 | 53 | 80 | 90 | |
380 | 3ø | 3/4 | 31 | 50 | 60 | |
416 | 3ø | 3/4 | 29 | 50 | 60 | |
|
|
|
|
|
| |
460/480 | 3ø | 3/4 | 30 | 50 | 60 | |
|
|
|
|
|
|
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is affixed to the right electrical control panel.
WARNING: 208 VAC and 230 VAC ARE NOT THE SAME. Any damage done to dryer components due to improper voltage connections will automatically VOID THE WARRANTY.
NOTE: ADC reserves the right to make any changes in specifications at any time without notice or obligation.