PAS4•S | 8 Service, maintenance and disposal |
|
|
MNA1MLSDM00EN, V2.01, 07.2009
8Service, maintenance and disposal
@DANGER
ELECTRIC SHOCK
High voltages at the motor connection may occur unexpectedly.
•Verify that no voltage is present (this includes the DC bus) prior to taking up work on the drive system.
•AC voltage can couple voltage to unused conductors in the motor cable. Insulate both ends of unused conductors in the motor cable.
•The motor generates voltage when the shaft is rotated. Prior to performing any type of work on the drive system, block the motor shaft to prevent rotation.
Failure to follow these instructions will result in death or serious injury.
@ WARNING
GREAT MASS OR FALLING PARTS
•Consider the mass of the axis when mounting it. It may be neces- sary to use a crane.
•Mount the axis in such a way (tightening torque, securing screws) that the axis and mounted parts cannot come loose even in the case of fast acceleration or continuous vibration.
•Note that vertically installed linear axes may lower unexpectedly.
Failure to follow these instructions can result in death, serious injury or equipment damage.
8.1Service address
If you cannot resolve an error yourself please contact your sales office.
Have the following details available:
•Nameplate (type, identification number, serial number, DOM, ...)
•Type of error (such as LED flash code or error number)
•Previous and concomitant circumstances
•Your own assumptions concerning the cause of the error
Also include this information if you return the product for inspection or re- pair.
If you have any questions please contact your sales office. Your sales office staff will be happy to give you the name of a customer service office in your area.
Portal axes with ball screw drive | 81 |