Setup
Resin Pump and Optional Heater Connections | Catalyst Pump Fluid Connections |
| NOTE: See FIG. 3 on page 14. |
| 11. Verify the pressure relief/recirculation valve (W) is |
| set to pressure relief (knob is horizontal). |
| M |
R | W |
| |
| ti21343a |
| ti18499c |
P
P1
N
FIG. 9: Catalyst Pump Pressure Relief Valve
12.Connect the catalyst line from the gun hose bundle to the catalyst outlet (Z1).
S
FIG. 8
6.Verify the pressure relief/recirculation valve (P) is set to pressure relief.
7.Place a waste container below the fluid outlet then remove the pump fluid inlet cap. Drain the test oil then discard.
8.Connect resin suction hose to the resin pump 3/4 nptm fluid inlet (S). Place other end of suction hose in resin container.
9.For
hose bundle.
For heated systems only: attach resin hose from the gun hose bundle to the heater outlet. Verify fluid hose connecting resin pump outlet to heater inlet is installed and secure.
10.Connect resin recirculation hose to the pressure relief/recirculation line (P1) and route to the resin container.
22 | 3A2012J |