Operation
Operation
Trigger Lock
Always engage the trigger lock when you stop spraying to prevent the gun from being triggered accidentally by hand or if dropped or bumped.
Boom Operation
ti18532b
The height of the boom can be adjusted by adjusting which link in the chain is secured to the boom arm.
Pressure Relief Procedure and Shutdown
The equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid such as skin injection, splashing fluid and moving parts, follow the Pressure Relief Proce- dure when you stop spraying and before cleaning, checking or servicing the equipment.
1. Close the main air supply ball valve.
NOTICE
Stop the pump at the bottom of its stroke to prevent fluid from drying on the exposed displacement rod and damaging the throat
2.Turn the main air supply pressure regulator fully
FIG. 10
3.Disengage the trigger lock on the gun. See FIG. 11.
4.With a grounded bucket below the gun, press the gun against the side of the bucket and pull the trig- ger to relieve pressure in the fluid lines.
FIG. 11
24 | 3A2012J |