Graco ti18526c, ti18524d, ti18496b specifications Accessories

Page 5

Accessories

Accessories

To avoid fire and explosion and electric shock, FRP proportioners are not approved for use in hazardous

locations unless all accessories, all kits, and all wiring meet local, state, and national codes. See Agency Approvals on page 3.

The following items can be purchased separately from

the system to gain additional functions. Many of the items require user installation; refer to the System Assembly section beginning on page 18 for the

required procedures.

Solvent Flush Diaphragm Pumps

Part Description

16M560

2 Gallon Solvent Flush Diaphragm Pump

 

 

16M561

5 Gallon Solvent Flush Diaphragm Pump

 

 

Solvent Flush Pressure Pots

Part

Description

 

 

16M874

2 Gallon, ASME and CE-approved, Solvent

Flush Pressure Pot

 

 

 

16M875

5 Gallon, ASME and CE-approved, Solvent

Flush Pressure Pot

 

 

 

16M893

2 Gallon, ASME Solvent Flush Pressure Pot

 

 

16M894

5 Gallon, ASME Solvent Flush Pressure Pot

 

 

Heaters

 

Part

Description

 

 

16N014

120V Viscon Heater, for hazardous loca-

tions

 

 

16N015

240V Viscon Heater, for hazardous loca-

tions

 

 

16N016

120V Viscon Heater, for hazardous loca-

tions and explosive atmospheres

 

 

 

16N017

240V Viscon Heater, for hazardous loca-

tions and explosive atmospheres

 

 

 

16N018

120V Viscon Heater, for non-hazardous

locations

 

 

 

16N019

240V Viscon Heater, for non-hazardous

locations

 

 

 

Heaters can be disassembled to remove

cured material.

 

 

 

Extension Hoses

Part

Description

 

 

16M712

25 ft Extension Hose Bundle for Chop Sys-

tems

 

 

 

16M718

25 ft Extension Hose Bundle for Internal Gel

Systems

 

 

 

16M719

25 ft Extension Hose Bundle for External

Gel Systems

 

55 Gallon Barrel Carts

Part Description

16M896 55 Gallon Barrel Cart

Roving Box Bracket

Part Description

16M961 Roving Box Bracket Kit

DataTrak Upgrade

Part Description

16M881 DataTrak Upgrade Kit

5 Gallon Catalyst Reservoir

Part Description

24M501 5 Gallon Catalyst Reservoir Kit

Wall Mounting

Part Description

16N918

FRP Pole or Wall Mount Kit

 

 

Pump Connecting Kits

Part

Description

 

 

16N242

17:1 Pump Connecting Kit

 

 

16N243

13:1 Pump Connecting Kit

 

 

3A2012J

5

Image 5
Contents FRP Proportioner Important Safety InstructionsContents Manual Description Related ManualsAgency Approvals No Cart Cart, Mast, and Boom ModelsHose Length RatioAccessories Skin Injection Hazard Toxic Fluid or Fumes Hazard 3A2012J Material Self-ignition Important Two-Component Material InformationChanging Materials Keep Resin and Catalyst Components SeparateTypical Applications OverviewKey Component IdentificationAir Control Panel Pressure relief/recirculation valve P relieves pres Air Motor and Resin Displacement PumpPressure relief/recirculation fluid outlet P1 place Pressurized fluid outlet on filter R connect fluidCatalyst Pump Components Catalyst PumpSolvent Flush Asme and CE-Approved Pressure Pot Solvent Flush SystemsSolvent Flush Diaphragm Pump Before Installation SetupLocation Requirements System Mounting Wall Mount Systems OnlyFor systems bolting directly to wall not using a pole For cart and boom systems only, install legs System AssemblySpring Chain Roving Guides Deflector Plates Grounding Ground WireAir Connections Connect Fluid and Air LinesCatalyst Pump Pressure Relief Valve Fill Supply Tanks Flush Before First UseSolvent Flush Connections if applicable Gun ConnectionsOperation Pressure Relief Procedure and ShutdownTrigger Lock Boom OperationOperation For internal mix proportioners only, check solvent line StartupPrime Follow Pressure Relief Procedure and Shut- down onOperation 3A2012J Flush External mix systems 30-40 psi 0.21-0.28 MPa, 2.1-2.8 bar SprayFollow Pressure Relief Procedure and Shutdown on AAC Air AdjustmentDataTrak Operation Run ModeSetup Mode Operation Solenoid Release Button Runaway MonitorPrime/Flush DiagnosticsCounter/Totalizer DisplayDiagnostic Codes Symbol Code Name Diagnosis Cause Disconnect DataTrak Replace DataTrak Battery or FuseTask Schedule Inspect pump wetcup Daily MaintenanceComponents Resin Pump TroubleshootingSpray pattern Mendations Fluid is too thin or too thick General Information Disconnect the Displacement PumpRepair Align cylinder and adapter plate Reconnect the Displacement PumpReconnect the Air Motor Disconnect the Air MotorTi18456c Replace Pumpline Remove Catalyst Pump from System Repair Catalyst PumpDisassemble Catalyst Pump Repair Throat and Piston SealsAssemble Catalyst Pump Repair Foot ValveCatalyst Pump Details Systems System Parts152 24M692 SPACER, ball joint Wall or Pole Mount KIT Wall or Pole Mount KIT Wall or Pole Mount KIT Quantity CartsSystem Parts Part Description Qty Wall or Pole Mount Kit, 16N918Boom, 16N761 Air Panel Slave Pump Linkage, 16P125 Part Description 131 171 Resin PumplinesAir Motor and Pump for Resin Pumpline Connecting KitGun Coupling CollarsMesh Pack Resin Filter24F620 16M736 Resin Supply Hose3A2012J 922 930 940 Catalyst Slave PumpsCatalyst Pumps Installation Tools not shown16P425 Catalyst ReservoirCart not included in kit, shown for reference only Hose Bundles Quantity 16N0169, 16N017, 16N018, and 16N019 Kits Accessory Parts Heater Kits16N014 and 16N015 Kits Nipple Asme Pressure Pots, 2-gallon 16M893 and 5-gallon 16M894 Solvent Pressure Pot KitsTube Asme and CE-Approved Pressure Pots, 16M874 and 16M875Gallon 16M560 and 5-gallon 16M561 Solvent Diaphragm Pumps16M881 DataTrak Upgrade KitCarts for 55 Gallon Barrel, 16M896 16M961 Roving Box BracketGel Hose Extension HosesChop Hose For external gelTop View DimensionsCart and Boom Wall/Pole Mount Cart OnlyPumpline Wall Mounting Bracket Dimensions Technical DataPumpline Technical Data 3A2012J Graco Information Graco Standard Warranty