Graco ti18524d, ti18496b, ti18526c specifications Skin Injection Hazard

Page 6

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.

WARNING

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:

• Use equipment only in well ventilated area.

• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc).

Keep work area free of debris, including solvent, rags and gasoline.

Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present.

Ground all equipment in the work area. See Grounding instructions.

Use only grounded hoses.

Hold gun firmly to side of grounded pail when triggering into pail.

If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.

Keep a working fire extinguisher in the work area.

SKIN INJECTION HAZARD

High-pressure fluid from dispensing device, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.

Engage trigger lock when not dispensing.

Do not point dispensing device at anyone or at any part of the body.

Do not put your hand over the fluid outlet.

Do not stop or deflect leaks with your hand, body, glove, or rag.

Follow the Pressure Relief Procedure when you stop dispensing and before cleaning, checking, or servicing equipment.

Tighten all fluid connections before operating the equipment.

Check hoses and couplings daily. Replace worn or damaged parts immediately.

ELECTRIC SHOCK HAZARD

This equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric shock.

Turn off and disconnect power at main switch before disconnecting any cables and before servicing equipment.

Connect only to grounded power source.

All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations.

6

3A2012J

Image 6
Contents Important Safety Instructions FRP ProportionerContents Related Manuals Agency ApprovalsManual Description Hose ModelsNo Cart Cart, Mast, and Boom Length RatioAccessories Skin Injection Hazard Toxic Fluid or Fumes Hazard 3A2012J Changing Materials Important Two-Component Material InformationMaterial Self-ignition Keep Resin and Catalyst Components SeparateOverview Typical ApplicationsComponent Identification KeyAir Control Panel Pressure relief/recirculation fluid outlet P1 place Air Motor and Resin Displacement PumpPressure relief/recirculation valve P relieves pres Pressurized fluid outlet on filter R connect fluidCatalyst Pump Catalyst Pump ComponentsSolvent Flush Systems Solvent Flush Diaphragm PumpSolvent Flush Asme and CE-Approved Pressure Pot Location Requirements SetupBefore Installation System Mounting Wall Mount Systems OnlyFor systems bolting directly to wall not using a pole System Assembly For cart and boom systems only, install legsSpring Chain Roving Guides Deflector Plates Ground Wire GroundingConnect Fluid and Air Lines Air ConnectionsCatalyst Pump Pressure Relief Valve Solvent Flush Connections if applicable Flush Before First UseFill Supply Tanks Gun ConnectionsTrigger Lock Pressure Relief Procedure and ShutdownOperation Boom OperationOperation Startup For internal mix proportioners only, check solvent lineFollow Pressure Relief Procedure and Shut- down on PrimeOperation 3A2012J Flush Spray External mix systems 30-40 psi 0.21-0.28 MPa, 2.1-2.8 barAAC Air Adjustment Follow Pressure Relief Procedure and Shutdown onRun Mode Setup ModeDataTrak Operation Operation Runaway Monitor Solenoid Release ButtonCounter/Totalizer DiagnosticsPrime/Flush DisplayDiagnostic Codes Symbol Code Name Diagnosis Cause Replace DataTrak Battery or Fuse Disconnect DataTrakMaintenance ComponentsTask Schedule Inspect pump wetcup Daily Troubleshooting Resin PumpSpray pattern Mendations Fluid is too thin or too thick Disconnect the Displacement Pump RepairGeneral Information Reconnect the Displacement Pump Align cylinder and adapter plateDisconnect the Air Motor Reconnect the Air MotorTi18456c Replace Pumpline Disassemble Catalyst Pump Repair Catalyst PumpRemove Catalyst Pump from System Repair Throat and Piston SealsRepair Foot Valve Assemble Catalyst PumpCatalyst Pump Details System Parts Systems152 24M692 SPACER, ball joint Wall or Pole Mount KIT Wall or Pole Mount KIT Wall or Pole Mount KIT Carts QuantitySystem Parts Wall or Pole Mount Kit, 16N918 Part Description QtyBoom, 16N761 Air Panel Slave Pump Linkage, 16P125 Resin Pumplines Part Description 131 171Gun Connecting KitAir Motor and Pump for Resin Pumpline Coupling CollarsResin Filter 24F620Mesh Pack Resin Supply Hose 16M7363A2012J Catalyst Slave Pumps 922 930 940Installation Tools not shown Catalyst PumpsCatalyst Reservoir 16P425Cart not included in kit, shown for reference only Hose Bundles Quantity Accessory Parts Heater Kits 16N014 and 16N015 Kits16N0169, 16N017, 16N018, and 16N019 Kits Nipple Solvent Pressure Pot Kits Asme Pressure Pots, 2-gallon 16M893 and 5-gallon 16M894Asme and CE-Approved Pressure Pots, 16M874 and 16M875 TubeSolvent Diaphragm Pumps Gallon 16M560 and 5-gallon 16M561DataTrak Upgrade Kit 16M881Carts for 55 Gallon Barrel, 16M896 Roving Box Bracket 16M961Chop Hose Extension HosesGel Hose For external gelDimensions Cart and BoomTop View Cart Only Wall/Pole MountTechnical Data Pumpline Wall Mounting Bracket DimensionsPumpline Technical Data 3A2012J Graco Standard Warranty Graco Information