Graco ti18526c, ti18524d, ti18496b specifications DataTrak Upgrade Kit, 16M881

Page 77

System Parts

DataTrak Upgrade Kit

16M881

1602

1602

Ref

Part

Description

Qty

1601 *

24A354

SMART AIR VALVE (not shown)

1

1602

24A576

DATATRAK CONVERSION KIT

1

* See FRP air motor manual.

3A2012J

77

Image 77
Contents FRP Proportioner Important Safety InstructionsContents Manual Description Related ManualsAgency Approvals No Cart Cart, Mast, and Boom ModelsHose Length RatioAccessories Skin Injection Hazard Toxic Fluid or Fumes Hazard 3A2012J Material Self-ignition Important Two-Component Material InformationChanging Materials Keep Resin and Catalyst Components SeparateTypical Applications OverviewKey Component IdentificationAir Control Panel Pressure relief/recirculation valve P relieves pres Air Motor and Resin Displacement PumpPressure relief/recirculation fluid outlet P1 place Pressurized fluid outlet on filter R connect fluidCatalyst Pump Components Catalyst PumpSolvent Flush Asme and CE-Approved Pressure Pot Solvent Flush SystemsSolvent Flush Diaphragm Pump Before Installation SetupLocation Requirements System Mounting Wall Mount Systems OnlyFor systems bolting directly to wall not using a pole For cart and boom systems only, install legs System AssemblySpring Chain Roving Guides Deflector Plates Grounding Ground WireAir Connections Connect Fluid and Air LinesCatalyst Pump Pressure Relief Valve Fill Supply Tanks Flush Before First UseSolvent Flush Connections if applicable Gun ConnectionsOperation Pressure Relief Procedure and ShutdownTrigger Lock Boom OperationOperation For internal mix proportioners only, check solvent line StartupPrime Follow Pressure Relief Procedure and Shut- down onOperation 3A2012J Flush External mix systems 30-40 psi 0.21-0.28 MPa, 2.1-2.8 bar SprayFollow Pressure Relief Procedure and Shutdown on AAC Air AdjustmentDataTrak Operation Run ModeSetup Mode Operation Solenoid Release Button Runaway MonitorPrime/Flush DiagnosticsCounter/Totalizer DisplayDiagnostic Codes Symbol Code Name Diagnosis Cause Disconnect DataTrak Replace DataTrak Battery or FuseTask Schedule Inspect pump wetcup Daily MaintenanceComponents Resin Pump TroubleshootingSpray pattern Mendations Fluid is too thin or too thick General Information Disconnect the Displacement PumpRepair Align cylinder and adapter plate Reconnect the Displacement PumpReconnect the Air Motor Disconnect the Air MotorTi18456c Replace Pumpline Remove Catalyst Pump from System Repair Catalyst PumpDisassemble Catalyst Pump Repair Throat and Piston SealsAssemble Catalyst Pump Repair Foot ValveCatalyst Pump Details Systems System Parts152 24M692 SPACER, ball joint Wall or Pole Mount KIT Wall or Pole Mount KIT Wall or Pole Mount KIT Quantity CartsSystem Parts Part Description Qty Wall or Pole Mount Kit, 16N918Boom, 16N761 Air Panel Slave Pump Linkage, 16P125 Part Description 131 171 Resin PumplinesAir Motor and Pump for Resin Pumpline Connecting KitGun Coupling CollarsMesh Pack Resin Filter24F620 16M736 Resin Supply Hose3A2012J 922 930 940 Catalyst Slave PumpsCatalyst Pumps Installation Tools not shown16P425 Catalyst ReservoirCart not included in kit, shown for reference only Hose Bundles Quantity 16N0169, 16N017, 16N018, and 16N019 Kits Accessory Parts Heater Kits16N014 and 16N015 Kits Nipple Asme Pressure Pots, 2-gallon 16M893 and 5-gallon 16M894 Solvent Pressure Pot KitsTube Asme and CE-Approved Pressure Pots, 16M874 and 16M875Gallon 16M560 and 5-gallon 16M561 Solvent Diaphragm Pumps16M881 DataTrak Upgrade KitCarts for 55 Gallon Barrel, 16M896 16M961 Roving Box BracketGel Hose Extension HosesChop Hose For external gelTop View DimensionsCart and Boom Wall/Pole Mount Cart OnlyPumpline Wall Mounting Bracket Dimensions Technical DataPumpline Technical Data 3A2012J Graco Information Graco Standard Warranty