Regency IG35-NG, IG35-LPG, IG35-ULPG Adjusting the Outlet Pressure, Cable Electric Modulator

Page 10

INSTALLATION

16)Turn on gas supply and plug in power cord.

17)Adjusting the Outlet Pressure

All the adjustments must be carried out in the following order:

Remove the modulator plastic cap (A) using needle nose pliers.

Maximum pressure: Turn the unit ON to its highest input rating. Screw in the nut (B) to increase the outlet pressure and screw it out to decrease it. Use a 10 mm wrench.

NOTE: The outlet pressure must be set to maximum 2.61 kPa.

Minimum pressure: Remove one of the cables connected to the electric modulator. While holding the nut (B) with a wrench, screw in the screw (C) to increase the pressure and screw it out to decrease it. Use a screwdriver 6 x 1 blade.

NOTE: The outlet pressure must be set to minimum 0.75 kPa.

After carrying out all adjustments, block the setting screws with paint, taking care not to obstruct the breather orifice of the pressure.

Put back the modulator plastic cap.

WARNING: To ensure the correct opera- tion of the modulator it is necessary that the plastic cap (A) is returned to its original location.

A

BC

Cable

Electric

Modulator

18)At the end of all setting and adjustment operations, check electrical installation and gas leaks.

19)Check operation of flame control.

20)Check for proper flame appearance and glow on logs.

Installer Notice:

These instructions must be left with the appliance.

10

Regency IG35 Gas Inbuilt Fireplace

Image 10
Contents Manual Please Keep These Instructions For Future ReferenceRegency GAS Inbuilt Fireplace Unit DimensionsRegency IG35 Gas Inbuilt Fireplace Table of Contents Data Badge Installation GAS Connection Minimum Fireplace DimensionsMinimum Clearances to Combustibles Premium Flush Front Framing GAS Pipe Pressure Testing FlueingMax. Input Aeration SettingsAeration Setting Min. InputAntenna Control Box Cover Jumper Location Heat ShieldAdjusting the Outlet Pressure Cable Electric ModulatorConversion Kit #486-967 for NG to Ulpg Installation Lava Rock LOG SET InstallationEmbersEmbers Example With care do not force into positionNotch Cutout NotchDiagram Side Faceplate Trim & Louver InstallationScreen Bracket Slots Premium Flush Front Installation Faceplate CAT5 CableTab into Tab Bracket Wire HarnessHeat Defl ector Bracket Diagram Regency IG35 Gas Inbuilt Fireplace Wire Harness RemovedIgnition Module Hinge Bracket Bottom LouverWiring Remote ControlFinal Check Wiring with Premium Flush Front Option Operating Instructions Copy of Lighting Instruction Plate Normal Operating Sounds GAS AppliancesDoor Glass Replacement MaintenanceMaintenance Instructions LOG ReplacementTo Remove Fan FAN MaintenanceBack Clip Removing Valve Tray Electronic Components Parts List Parts List910-084 Burner Assembly & LOG SET Main AssemblyDescription Faceplate Assembly Premium Flush Front AssemblyConditions WarrantyWarranty Lifetime Exclusions