Regency IG35-LPG Minimum Fireplace Dimensions, Minimum Clearances to Combustibles, GAS Connection

Page 6

INSTALLATION

MINIMUM FIREPLACE

DIMENSIONS

The minimum fireplace dimensions for the Regency gas space heater are shown in the following diagrams:

MINIMUM

CLEARANCES TO

COMBUSTIBLES

The minimum fireplace clearances for the Regency gas space heater are shown in the following diagrams:

Mantel Clearances

Premium Flush Front Framing

When installing the Premium Flush Front, the walls surrounding the zero clearance kit must be made of non-combustible material. See Diagram below.

From Unit:

 

 

Sides

A

250 mm

Ceiling

B

1220 mm

Mantel

C

see Mantel

 

 

Clearances

From Surround (660 mm x 1016 mm):

Sides

D

96 mm

Ceiling

E

1066 mm

Max. Mantle Depth

G

305 mm

Hearth Height

H

0 mm

Hearth Depth

I

300 mm*

Hearth Width

J

1100 mm

Min. Alcove Width

K

1262 mm

Max. Alcove Depth

L

915 mm

*NOTE: No hearth required with screen. Floor finishing material must not be any higher then the base of the fireplace.

Note: A non-combustible mantel may be installed at a lower height if the fram- ing is made of metal studs covered with a non-combustible board.

GAS CONNECTION

GAS CONNECTION WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance.

1)If the appliance is to be installed into an existing chimney system or Zero Clearance Box, thoroughly clean the masonry or factory built fireplace.

2)The gas connection is 1/2" BSP.

3)Locate the center point where the flue will pass through the chimney above the appli- ance. Move the appliance into the exact location where it is to be installed. Ensure that the Insert is level.

CAUTION: If the glass is removed for servic- ing, it must be replaced and closed prior to operating the appliance.

6

Regency IG35 Gas Inbuilt Fireplace

Image 6
Contents Manual Please Keep These Instructions For Future ReferenceUnit Dimensions Regency GAS Inbuilt FireplaceRegency IG35 Gas Inbuilt Fireplace Table of Contents Data Badge Installation GAS Connection Minimum Fireplace DimensionsMinimum Clearances to Combustibles Premium Flush Front FramingGAS Pipe Pressure Testing FlueingMax. Input Aeration SettingsAeration Setting Min. InputAntenna Control Box Cover Jumper Location Heat ShieldAdjusting the Outlet Pressure Cable Electric ModulatorConversion Kit #486-967 for NG to Ulpg Installation LOG SET Installation Lava RockEmbersEmbers Example With care do not force into positionNotch Cutout NotchFaceplate Trim & Louver Installation Diagram SideScreen Bracket Slots Premium Flush Front Installation Faceplate CAT5 CableWire Harness Tab into Tab BracketHeat Defl ector Wire Harness Removed Bracket Diagram Regency IG35 Gas Inbuilt FireplaceIgnition Module Hinge Bracket Bottom LouverRemote Control WiringFinal Check Wiring with Premium Flush Front Option Operating Instructions Copy of Lighting Instruction Plate Normal Operating Sounds GAS AppliancesDoor Glass Replacement MaintenanceMaintenance Instructions LOG ReplacementFAN Maintenance To Remove FanBack Clip Removing Valve Tray Parts List Electronic Components Parts List910-084 Main Assembly Burner Assembly & LOG SETDescription Faceplate Assembly Premium Flush Front AssemblyConditions WarrantyWarranty Lifetime Exclusions