INSTALLATION

FACEPLATE,

TRIM & LOUVER

INSTALLATION

1)Lay the faceplate panels flat, face down on something soft so they don't scratch.

2)Take the top faceplate and align the holes in it with the holes in the side panels. Us- ing the screws provided, attach from the top of the panel (the holes in the top panel are slightly larger than the holes in the side panel to facilitate easier installation).

4)Connect the fan harness to the fan switch.

5)Connect the valve harness to the valve on/off switch.

6)Tuck the wires into the faceplate to keep them away from the inbuilt fireplace using the clip provided. Attach the clip to the rear of the faceplate to ensure that the wires do not touch the side of the unit.

7)The power cord should be run behind the faceplate panel.

10)Push the Regency logo plate into the two holes in the bottom left corner of the face- plate.

11)Place the 2 hinges for the bottom louver in position and secure using 4 screws per hinge.

12)Place the bottom louver in position and secure it with 6 screws.

8) Place the trim on the assembled faceplate

13) Install the safety screen by inserting the 4

panels and secure it with the side screws.

screen brackets into the 4 slots.

Diagram 1

Hint: Don't tighten the trim to the bottom of the faceplate side panels with the screws provided. See diagram 1.

3)Using the connectors provided, join the left side trim to the top trim. Connect the right side trim to the top trim.

Screen

Bracket

Slots

 

14) Install the top louver by sliding the 2 bracket

9) Attach the faceplate panels* to the inbuilt

clips into the brackets located on top of the

fireplace body using 4 black screws.

unit.

Diagram 2

Side

Rear View: Trim Assembly

Screws

 

Regency IG35 Gas Inbuilt Fireplace

15

Image 15
Contents Please Keep These Instructions For Future Reference ManualUnit Dimensions Regency GAS Inbuilt FireplaceRegency IG35 Gas Inbuilt Fireplace Table of Contents Data Badge Installation Premium Flush Front Framing Minimum Fireplace DimensionsMinimum Clearances to Combustibles GAS ConnectionFlueing GAS Pipe Pressure TestingMin. Input Aeration SettingsAeration Setting Max. InputJumper Location Heat Shield Antenna Control Box CoverCable Electric Modulator Adjusting the Outlet PressureConversion Kit #486-967 for NG to Ulpg Installation LOG SET Installation Lava RockEmbersEmbers Notch With care do not force into positionNotch Cutout ExampleFaceplate Trim & Louver Installation Diagram SideScreen Bracket Slots Premium Flush Front Installation CAT5 Cable FaceplateWire Harness Tab into Tab BracketHeat Defl ector Wire Harness Removed Bracket Diagram Regency IG35 Gas Inbuilt FireplaceIgnition Module Bottom Louver Hinge BracketRemote Control WiringFinal Check Wiring with Premium Flush Front Option Operating Instructions Normal Operating Sounds GAS Appliances Copy of Lighting Instruction PlateLOG Replacement MaintenanceMaintenance Instructions Door Glass ReplacementFAN Maintenance To Remove FanBack Clip Removing Valve Tray Parts List Electronic Components Parts List910-084 Main Assembly Burner Assembly & LOG SETDescription Premium Flush Front Assembly Faceplate AssemblyExclusions WarrantyWarranty Lifetime Conditions