Regency IG35-ULPG, IG35-LPG, IG35-NG installation manual Conversion Kit #486-967 for NG to Ulpg

Page 11

INSTALLATION

Conversion Kit #486-967 for NG to ULPG

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!

Conversion Kit 486-967 Contains:

Qty. Part # Description

1904-345 Burner Orifice #53

1918-273 Red "ULPG" label

1918-272 Label "Converted to ULPG"

1918-542 Instruction Sheet

1)Shut off the gas supply and unplug the power cord.

2)Remove the front door.

3)Remove logs.

4)Remove the rear log tray by removing the 2 screws. (Log tray must be rotated to clear the burner.)

7)Remove burner orifice with a 1/2" wrench and discard. Use a wrench to hold on to the elbow behind the orifice.

8)Reinstall new burner orifice ULPG stamped #53 and tighten.

9)Stick the conversion label "This unit has been converted to ULPG" over top of the serial number decal.

10)Replace the yellow "NG" label with the red "ULPG" label.

11)Carefully pull out the control box.

NOTE: The control box is held in place with velcro.

12)Remove the heat shield from the control box by removing the 2 screws.

13)Remove the control box cover by undoing the 3 screws. Maneuver through antenna.

Antenna

Control Box

Cover

14)Remove the jumper using a plier.

5)Remove the grate.

6)Remove the burner and adjust the aeration setting to 15 mm fully open.

Jumper Location

Jumper

Heat Shield

15)Reverse steps 13, 12, 11, 6, 5, 4, 3 & 2.

Regency IG35 Gas Inbuilt Fireplace

11

Image 11
Contents Please Keep These Instructions For Future Reference ManualRegency IG35 Gas Inbuilt Fireplace Unit DimensionsRegency GAS Inbuilt Fireplace Table of Contents Data Badge Installation Premium Flush Front Framing Minimum Fireplace DimensionsMinimum Clearances to Combustibles GAS ConnectionFlueing GAS Pipe Pressure TestingMin. Input Aeration SettingsAeration Setting Max. InputJumper Location Heat Shield Antenna Control Box CoverCable Electric Modulator Adjusting the Outlet PressureConversion Kit #486-967 for NG to Ulpg Installation EmbersEmbers LOG SET InstallationLava Rock Notch With care do not force into positionNotch Cutout ExampleScreen Bracket Slots Faceplate Trim & Louver InstallationDiagram Side Premium Flush Front Installation CAT5 Cable FaceplateHeat Defl ector Wire HarnessTab into Tab Bracket Ignition Module Wire Harness RemovedBracket Diagram Regency IG35 Gas Inbuilt Fireplace Bottom Louver Hinge BracketFinal Check Remote ControlWiring Wiring with Premium Flush Front Option Operating Instructions Normal Operating Sounds GAS Appliances Copy of Lighting Instruction PlateLOG Replacement MaintenanceMaintenance Instructions Door Glass ReplacementBack Clip FAN MaintenanceTo Remove Fan Removing Valve Tray 910-084 Parts ListElectronic Components Parts List Description Main AssemblyBurner Assembly & LOG SET Premium Flush Front Assembly Faceplate AssemblyExclusions WarrantyWarranty Lifetime Conditions

IG35-LPG, IG35-ULPG, IG35-NG specifications

The Regency IG35-NG, IG35-ULPG, and IG35-LPG represent a trio of advanced heating solutions designed to cater to various fuel types while maintaining efficiency and user comfort. These units are ideal for modern residences and commercial spaces, showcasing technological advancements in the heating sector.

The IG35-NG operates on natural gas, offering an environmentally friendly solution with lower emissions compared to traditional heating methods. Its ability to provide consistent heat while being energy efficient makes it an attractive option for both new builds and retrofits. Featuring an automatic ignition system, the IG35-NG ensures quick and hassle-free operation, allowing users to enjoy immediate warmth.

For those in regions where propane is more accessible, the IG35-ULPG caters specifically to ultra-low propane gas environments. This model boasts similar performance metrics to the IG35-NG but is optimized for utilizing propane under lower pressure. The advanced burner technology employed in the IG35-ULPG tracks combustion efficiency and significantly reduces fuel consumption, making it both cost-effective and eco-friendly.

The IG35-LPG, on the other hand, is tailored for standard liquefied petroleum gas applications. Ideal for areas lacking natural gas infrastructure, this model ensures that users can still benefit from efficient heating solutions. The IG35-LPG incorporates sophisticated safety features, including flame failure detection and automatic shut-off systems. This ensures peace of mind for users by minimizing risks related to gas leaks and other potential hazards.

All three models share a sleek design, fitting seamlessly into various interior aesthetics. The compact size enhances installation flexibility, allowing these heaters to fit into spaces where traditional heating units may not suffice. Moreover, they come equipped with user-friendly controls that facilitate easy adjustments to temperature settings, ensuring optimal comfort during cold seasons.

In terms of energy efficiency, these heaters carry exceptional ratings, which may even qualify them for rebates and incentives in many regions. The advanced heat exchanger technology employed in these units allows for maximum heat transfer while minimizing waste, thus serving the dual purpose of reducing heating costs and environmental impact.

Overall, the Regency IG35 series presents a versatile and efficient lineup of heating solutions. With their modern technologies, user-centric features, and commitment to safety and efficiency, the IG35-NG, IG35-ULPG, and IG35-LPG represent the next generation of heating for both residential and commercial applications.