Regency IG35-ULPG, IG35-LPG, IG35-NG installation manual Hinge Bracket, Bottom Louver

Page 20

INSTALLATION

25)Secure all loose wires in the wire clip to the right side of the valve. See diagram 23.

Diagram 23

Screen Door Installation:

28)Re-install the glass door.

29)Install the screen by placing the hooks (2 on each side) into the slots on the inside of the faceplate. Once in place, push down on the screen to secure. See diagram 26.

Louver Installation:

26)Secure the hinge bracket and hinge to the outside of the fi rebox fl ange on the left and right side as shown using 2 screws on each side. See diagram 24.

Hinge Bracket

Hinge

Diagram 24

27)Align the bottom louver hinge tab screw holes with hinge screw holes and secure using 3 screws on each side. See diagram 25.

Bottom Louver

Diagram 25

Diagram 26

30)Close the bottom louver.

31)Plug in the power source.

NOTE:

The fan should run at least on low speed to prevent the unit from overheating which will cause automatic shutdown via the thermodisc safety switch.

20

Regency IG35 Gas Inbuilt Fireplace

Image 20
Contents Manual Please Keep These Instructions For Future ReferenceRegency IG35 Gas Inbuilt Fireplace Unit DimensionsRegency GAS Inbuilt Fireplace Table of Contents Data Badge Installation Minimum Fireplace Dimensions Minimum Clearances to CombustiblesGAS Connection Premium Flush Front FramingGAS Pipe Pressure Testing FlueingAeration Settings Aeration SettingMax. Input Min. InputAntenna Control Box Cover Jumper Location Heat ShieldAdjusting the Outlet Pressure Cable Electric ModulatorConversion Kit #486-967 for NG to Ulpg Installation EmbersEmbers LOG SET InstallationLava Rock With care do not force into position Notch CutoutExample NotchScreen Bracket Slots Faceplate Trim & Louver InstallationDiagram Side Premium Flush Front Installation Faceplate CAT5 CableHeat Defl ector Wire HarnessTab into Tab Bracket Ignition Module Wire Harness RemovedBracket Diagram Regency IG35 Gas Inbuilt Fireplace Hinge Bracket Bottom LouverFinal Check Remote ControlWiring Wiring with Premium Flush Front Option Operating Instructions Copy of Lighting Instruction Plate Normal Operating Sounds GAS AppliancesMaintenance Maintenance InstructionsDoor Glass Replacement LOG ReplacementBack Clip FAN MaintenanceTo Remove Fan Removing Valve Tray 910-084 Parts ListElectronic Components Parts List Description Main AssemblyBurner Assembly & LOG SET Faceplate Assembly Premium Flush Front AssemblyWarranty Warranty LifetimeConditions Exclusions

IG35-LPG, IG35-ULPG, IG35-NG specifications

The Regency IG35-NG, IG35-ULPG, and IG35-LPG represent a trio of advanced heating solutions designed to cater to various fuel types while maintaining efficiency and user comfort. These units are ideal for modern residences and commercial spaces, showcasing technological advancements in the heating sector.

The IG35-NG operates on natural gas, offering an environmentally friendly solution with lower emissions compared to traditional heating methods. Its ability to provide consistent heat while being energy efficient makes it an attractive option for both new builds and retrofits. Featuring an automatic ignition system, the IG35-NG ensures quick and hassle-free operation, allowing users to enjoy immediate warmth.

For those in regions where propane is more accessible, the IG35-ULPG caters specifically to ultra-low propane gas environments. This model boasts similar performance metrics to the IG35-NG but is optimized for utilizing propane under lower pressure. The advanced burner technology employed in the IG35-ULPG tracks combustion efficiency and significantly reduces fuel consumption, making it both cost-effective and eco-friendly.

The IG35-LPG, on the other hand, is tailored for standard liquefied petroleum gas applications. Ideal for areas lacking natural gas infrastructure, this model ensures that users can still benefit from efficient heating solutions. The IG35-LPG incorporates sophisticated safety features, including flame failure detection and automatic shut-off systems. This ensures peace of mind for users by minimizing risks related to gas leaks and other potential hazards.

All three models share a sleek design, fitting seamlessly into various interior aesthetics. The compact size enhances installation flexibility, allowing these heaters to fit into spaces where traditional heating units may not suffice. Moreover, they come equipped with user-friendly controls that facilitate easy adjustments to temperature settings, ensuring optimal comfort during cold seasons.

In terms of energy efficiency, these heaters carry exceptional ratings, which may even qualify them for rebates and incentives in many regions. The advanced heat exchanger technology employed in these units allows for maximum heat transfer while minimizing waste, thus serving the dual purpose of reducing heating costs and environmental impact.

Overall, the Regency IG35 series presents a versatile and efficient lineup of heating solutions. With their modern technologies, user-centric features, and commitment to safety and efficiency, the IG35-NG, IG35-ULPG, and IG35-LPG represent the next generation of heating for both residential and commercial applications.