Regency IG35-NG, IG35-LPG, IG35-ULPG installation manual Wire Harness Removed, Ignition Module

Page 19

INSTALLATION

19)Carefully lift off the ignition module from the velcro and slightly bring forward. Remove the wire harness connected to the ignition module as shown in diagram 17.

22)Connect the other end of the new wire harness to the valve, in place of the one removed in step 16. See diagram 20.

Wire Harness

Removed

Diagram 17

Ignition

 

 

Module

Diagram 20

 

 

20)Discard the complete wire harness that was connected to the valve and ignition module.

21)Take the wire harness included with the kit and connect one end of the wire harness to the ignition module (in place of the one removed), see diagram 18 .

Place the ignition module back on the velcro at the base of the fi rebox. Ensure to run the loose wires from the wire harness in behind the bracket on the left side of the ignition module. See diagram 19.

Diagram 18

23)Disconnect the red split wires from the wire harness as shown in diagram 21.

Diagram 21

24)Feed the remaining thermodisc wires thru the opening on the bottom of the left side of the fi rebox and run them in behind the bracket to the left of the valve. See diagram 22.

Connect the 2 wires from the thermodisc to the appropriate wire on the harness; female to male, male to female.

 

Bracket

Diagram 22

Diagram 19

Bracket

 

 

 

 

 

 

 

 

 

Regency IG35 Gas Inbuilt Fireplace

 

19

Image 19
Contents Please Keep These Instructions For Future Reference ManualRegency GAS Inbuilt Fireplace Unit DimensionsRegency IG35 Gas Inbuilt Fireplace Table of Contents Data Badge Installation Premium Flush Front Framing Minimum Fireplace DimensionsMinimum Clearances to Combustibles GAS ConnectionFlueing GAS Pipe Pressure TestingMin. Input Aeration SettingsAeration Setting Max. InputJumper Location Heat Shield Antenna Control Box CoverCable Electric Modulator Adjusting the Outlet PressureConversion Kit #486-967 for NG to Ulpg Installation Lava Rock LOG SET InstallationEmbersEmbers Notch With care do not force into positionNotch Cutout ExampleDiagram Side Faceplate Trim & Louver InstallationScreen Bracket Slots Premium Flush Front Installation CAT5 Cable FaceplateTab into Tab Bracket Wire HarnessHeat Defl ector Bracket Diagram Regency IG35 Gas Inbuilt Fireplace Wire Harness RemovedIgnition Module Bottom Louver Hinge BracketWiring Remote ControlFinal Check Wiring with Premium Flush Front Option Operating Instructions Normal Operating Sounds GAS Appliances Copy of Lighting Instruction PlateLOG Replacement MaintenanceMaintenance Instructions Door Glass ReplacementTo Remove Fan FAN MaintenanceBack Clip Removing Valve Tray Electronic Components Parts List Parts List910-084 Burner Assembly & LOG SET Main AssemblyDescription Premium Flush Front Assembly Faceplate AssemblyExclusions WarrantyWarranty Lifetime Conditions