INSTALLATION
System Data
IG35
TEST FOR FLUE | OPTIONAL |
SPILLAGE | BRICK PANEL |
Burner Inlet Orifice Sizes: |
| |
NG | LPG | ULPG |
Burner #33 | #51 | #53 |
|
|
|
Max. Input |
|
|
NG | 33.5 mj |
|
LPG | 34 mj |
|
ULPG | 28 mj |
|
|
|
|
Min. Input |
|
|
NG | 19.6 mj |
|
LPG | 18.5 mj |
|
ULPG | 14 mj |
|
|
|
|
Supply Pressure |
|
|
NG | 1.13 kPa |
|
LPG | 2.75 kPa |
|
ULPG | 2.75 kPa |
|
|
|
|
Manifold Pressure |
|
|
NG | 0.87 kPa |
|
LPG | 2.61 kPa |
|
ULPG | 2.61 kPa |
|
Electrical: 240 V. 50Hz.
Circulation: High/Off/LO speed fan, 150/89 CFM.
Log Set: Ceramic fiber, 7 per set.
Aeration Setting
NG | 15mm fully open |
LPG | 15mm fully open |
ULPG | 15mm fully open |
A " spillage" test must be made before the installed unit is left with the customer. Follow the procedure below:
1)Start all exhaust fans in the home and then close all external doors and windows in the house.
2)Light the unit and set controls to maximum. Turn fan off.
3)After five minutes, test that there is a “pull” on the flue by placing a smoke match, cigarette or similar device which gives off smoke, in both sides of the unit. See diagram 1.
Diagram 1
1)Unwrap the brick panels from the protective wrapping.
2)Remove the glass front and log set if already installed.
3)Place the rear brick panel flat against the back of the unit, by carefully slipping it be- tween the back wall of the firebox and the rear log tray.
4)Remove the screw on the inside top left and right side of the firebox.
LeftSide
ofFirebox
Rem ove screw
5)Slide the left and right side brick panels in place and secure using the brick retaining clips provided and the screws removed in step 4 as shown in the diagram below.
AERATION SETTINGS
The burner aeration is factory set but may need adjusting due to either the local gas supply, air supply or altitude. This adjustment is performed by the installer. (Close the aeration for a more yellow flame, or open it to make the flame bluer).
NG: | 15mm fully open |
LPG: | 15mm fully open |
ULPG: | 15mm fully open |
Note: Any damage due to carboning result- ing from improperly setting the aera- tion controls is NOT covered under warranty.
The smoke should be drawn into the unit. If the smoke is still not drawn into the spill tube, turn the unit off and check for the cause of the lack of draft. If necessary, rectify.
For wind turbulent sites, a wind cap may rem- edy the problem. These caps are not included with the standard flue kit and will need to be purchased separately.
Screw
| Brick |
| R etaining |
| C lip |
Back |
|
brick |
|
panel | Side |
| |
| brick |
| panel |
8 | Regency IG35 Gas Inbuilt Fireplace |