Regency IG35-ULPG, IG35-LPG, IG35-NG installation manual FAN Maintenance, To Remove Fan, Back Clip

Page 26

MAINTENANCE

FAN MAINTENANCE

To Remove Fan:

1)Turn the unit off and allow it to cool to room temperature,

2)Unplug or disconnect power source to stove.

3)Open the bottom louvre.

4)Remove the ECS harness from the back clip.

6)Pull out the ECS box.

NOTE: The ECS box is held in place with velcro.

7)Carefully slide the fan to the front, rotate it 45 degrees and slide it out simultaneously with the ECS box.

Back Clip

5)Remove the 2 screws that secure the fan in place.

Resistor Con-

Fan

Fan Ground

nectors

Connectors

Cable

8)Disconnect all the connectors from the fan and resistor.

9)Remove the fan ground cable.

10)Pull out the fan tray.

11)Remove the 3 screws from the back of the fan tray to remove the fan.

12)Reverse the above steps to install the new fan.

26

Regency IG35 Gas Inbuilt Fireplace

Image 26
Contents Manual Please Keep These Instructions For Future ReferenceRegency IG35 Gas Inbuilt Fireplace Unit DimensionsRegency GAS Inbuilt Fireplace Table of Contents Data Badge Installation GAS Connection Minimum Fireplace DimensionsMinimum Clearances to Combustibles Premium Flush Front FramingGAS Pipe Pressure Testing FlueingMax. Input Aeration SettingsAeration Setting Min. InputAntenna Control Box Cover Jumper Location Heat ShieldAdjusting the Outlet Pressure Cable Electric ModulatorConversion Kit #486-967 for NG to Ulpg Installation EmbersEmbers LOG SET InstallationLava Rock Example With care do not force into positionNotch Cutout NotchScreen Bracket Slots Faceplate Trim & Louver InstallationDiagram Side Premium Flush Front Installation Faceplate CAT5 CableHeat Defl ector Wire HarnessTab into Tab Bracket Ignition Module Wire Harness RemovedBracket Diagram Regency IG35 Gas Inbuilt Fireplace Hinge Bracket Bottom LouverFinal Check Remote ControlWiring Wiring with Premium Flush Front Option Operating Instructions Copy of Lighting Instruction Plate Normal Operating Sounds GAS AppliancesDoor Glass Replacement MaintenanceMaintenance Instructions LOG ReplacementBack Clip FAN MaintenanceTo Remove Fan Removing Valve Tray 910-084 Parts ListElectronic Components Parts List Description Main AssemblyBurner Assembly & LOG SET Faceplate Assembly Premium Flush Front AssemblyConditions WarrantyWarranty Lifetime Exclusions

IG35-LPG, IG35-ULPG, IG35-NG specifications

The Regency IG35-NG, IG35-ULPG, and IG35-LPG represent a trio of advanced heating solutions designed to cater to various fuel types while maintaining efficiency and user comfort. These units are ideal for modern residences and commercial spaces, showcasing technological advancements in the heating sector.

The IG35-NG operates on natural gas, offering an environmentally friendly solution with lower emissions compared to traditional heating methods. Its ability to provide consistent heat while being energy efficient makes it an attractive option for both new builds and retrofits. Featuring an automatic ignition system, the IG35-NG ensures quick and hassle-free operation, allowing users to enjoy immediate warmth.

For those in regions where propane is more accessible, the IG35-ULPG caters specifically to ultra-low propane gas environments. This model boasts similar performance metrics to the IG35-NG but is optimized for utilizing propane under lower pressure. The advanced burner technology employed in the IG35-ULPG tracks combustion efficiency and significantly reduces fuel consumption, making it both cost-effective and eco-friendly.

The IG35-LPG, on the other hand, is tailored for standard liquefied petroleum gas applications. Ideal for areas lacking natural gas infrastructure, this model ensures that users can still benefit from efficient heating solutions. The IG35-LPG incorporates sophisticated safety features, including flame failure detection and automatic shut-off systems. This ensures peace of mind for users by minimizing risks related to gas leaks and other potential hazards.

All three models share a sleek design, fitting seamlessly into various interior aesthetics. The compact size enhances installation flexibility, allowing these heaters to fit into spaces where traditional heating units may not suffice. Moreover, they come equipped with user-friendly controls that facilitate easy adjustments to temperature settings, ensuring optimal comfort during cold seasons.

In terms of energy efficiency, these heaters carry exceptional ratings, which may even qualify them for rebates and incentives in many regions. The advanced heat exchanger technology employed in these units allows for maximum heat transfer while minimizing waste, thus serving the dual purpose of reducing heating costs and environmental impact.

Overall, the Regency IG35 series presents a versatile and efficient lineup of heating solutions. With their modern technologies, user-centric features, and commitment to safety and efficiency, the IG35-NG, IG35-ULPG, and IG35-LPG represent the next generation of heating for both residential and commercial applications.