Regency IG35-LPG, IG35-NG, IG35-ULPG installation manual Remote Control, Final Check, Wiring

Page 21

INSTALLATION

REMOTE CONTROL

Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warranty.

The remote control kit comes with a hand held transmitter and a wall mounting plate.

1)Choose a convenient location to mount the hand held transmitter, protection from extreme heat is very important.

By usiing the wall mounting plate to house the transmitter, the remote can also be used as a wall thermostat.

FINAL CHECK

Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly. This includes:

1)Clocking the appliance to ensure the cor- rect firing rate (rate noted on label) at 15 minutes.

2)If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15 min. to stabilize.

3)Check for proper draft.

CAUTION

Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the responsibility of the

Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges.

WIRING

This unit is polarity sensitive and will not operate if polarity is incorrect.

STANDARD WIRING

Regency IG35 Gas Inbuilt Fireplace

21

Image 21
Contents Please Keep These Instructions For Future Reference ManualUnit Dimensions Regency GAS Inbuilt FireplaceRegency IG35 Gas Inbuilt Fireplace Table of Contents Data Badge Installation Minimum Clearances to Combustibles Minimum Fireplace DimensionsGAS Connection Premium Flush Front FramingFlueing GAS Pipe Pressure TestingAeration Setting Aeration SettingsMax. Input Min. InputJumper Location Heat Shield Antenna Control Box CoverCable Electric Modulator Adjusting the Outlet PressureConversion Kit #486-967 for NG to Ulpg Installation LOG SET Installation Lava RockEmbersEmbers Notch Cutout With care do not force into positionExample NotchFaceplate Trim & Louver Installation Diagram SideScreen Bracket Slots Premium Flush Front Installation CAT5 Cable Faceplate Wire Harness Tab into Tab Bracket Heat Defl ector Wire Harness Removed Bracket Diagram Regency IG35 Gas Inbuilt FireplaceIgnition Module Bottom Louver Hinge BracketRemote Control WiringFinal Check Wiring with Premium Flush Front Option Operating Instructions Normal Operating Sounds GAS Appliances Copy of Lighting Instruction PlateMaintenance Instructions MaintenanceDoor Glass Replacement LOG ReplacementFAN Maintenance To Remove FanBack Clip Removing Valve Tray Parts List Electronic Components Parts List910-084 Main Assembly Burner Assembly & LOG SETDescription Premium Flush Front Assembly Faceplate AssemblyWarranty Lifetime WarrantyConditions Exclusions