Regency IG35-ULPG, IG35-LPG, IG35-NG installation manual Operating Instructions

Page 23

OPERATING INSTRUCTIONS

OPERATING

INSTRUCTIONS

Before operating this appliance, proceed through the following check list.

1)Read and understand these Instructions before operating this appliance.

2)Check to see that all wiring is correct and enclosed to prevent possible shock.

3)Check to ensure there are no gas leaks.

4)Make sure the glass door is in place. Never operate the appliance with the door glass removed.

5)Verify that all flueing and the cap is unob- structed.

6)Verify log placement.

7)The unit should never be turned off and on again without a minimum of a 60 second wait.

8)When lighting the appliance, the inside of the glass may fog up. This will burn off after a few minutes of operation.

LIGHTING

INSTRUCTIONS

1)Plug the power cord into a power outlet.

2)Press and release the ON/OFF switch once to start the unit. The LED will be lit.

3)After approximately 8 seconds the spark ignition system will spark for 8 seconds to light the main burner.

4)If the main burner does not light, repeat step 2 to restart the unit.

FIRST FIRE

The FIRST FIRE in your heater is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fireplace for at least four (4) hours the first time you use it with the fan on.

When first operated, the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining from manufac- turing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours. The glass may require cleaning.

NOTE: The main burner will always start on "HIGH" and resume it's last setting after 20 seconds of operation.

NOTE: When the glass is cold and the appliance is lit, it may cause condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.

DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT!

DO NOT BURN THE APPLIANCE WITH- OUT THE GLASS FRONT IN PLACE.

FAN OPERATION

Set the fan speed on the control panel at the top rear of the unit to adjust to the desired speed.

Pressing and releasing the plus (+) FAN button will change the fan speed as follows:

OFF -> LOW -> MEDIUM -> HIGH -> OFF, etc.

Pressing and releasing the minus (-) FAN button will be the reverse of the above.

ADJUSTING FLAME

HEIGHT

There are six flame settings that can be adjusted by pressing and releasing the plus (+) and minus (-) FLAME button.

The FLAME setting button is located on the control panel at the top rear of the unit.

SUMMARY OF

CONTROLS

On/Off Button

If the unit is switched off, pressing and releasing this button once will switch the unit on. The unit will resume its last settings.

If the unit is switched on, pressing and releasing this button once will switch the unit off.

Flame:

Increase - If the unit is switched on, pressing and releasing the flame plus (+) button once will increase the flame height to the next available high setting.

Decrease - If the unit is switched on, pressing and releasing the flame minus (-) button once will decrease the flame height to the next avail- able low setting.

Fan:

Increase - If the unit is switched on, pressing and releasing the fan plus (+) button once will increase the fan speed to the next available high setting.

Decrease - If the unit is switched on, pressing and releasing the fan minus (-) button once will decrease the fan speed to the next available low setting.

SHUTDOWN

INSTRUCTIONS

1)Press the ON/OFF switch once.

2)The LED will flash.

3)Turn off all electric power to the appliance if service is to be performed.

Regency IG35 Gas Inbuilt Fireplace

23

Image 23
Contents Please Keep These Instructions For Future Reference ManualRegency IG35 Gas Inbuilt Fireplace Unit DimensionsRegency GAS Inbuilt Fireplace Table of Contents Data Badge Installation Premium Flush Front Framing Minimum Fireplace DimensionsMinimum Clearances to Combustibles GAS ConnectionFlueing GAS Pipe Pressure TestingMin. Input Aeration SettingsAeration Setting Max. InputJumper Location Heat Shield Antenna Control Box CoverCable Electric Modulator Adjusting the Outlet PressureConversion Kit #486-967 for NG to Ulpg Installation EmbersEmbers LOG SET InstallationLava Rock Notch With care do not force into positionNotch Cutout ExampleScreen Bracket Slots Faceplate Trim & Louver InstallationDiagram Side Premium Flush Front Installation CAT5 Cable FaceplateHeat Defl ector Wire HarnessTab into Tab Bracket Ignition Module Wire Harness RemovedBracket Diagram Regency IG35 Gas Inbuilt Fireplace Bottom Louver Hinge BracketFinal Check Remote ControlWiring Wiring with Premium Flush Front Option Operating Instructions Normal Operating Sounds GAS Appliances Copy of Lighting Instruction PlateLOG Replacement MaintenanceMaintenance Instructions Door Glass ReplacementBack Clip FAN MaintenanceTo Remove Fan Removing Valve Tray 910-084 Parts ListElectronic Components Parts List Description Main AssemblyBurner Assembly & LOG SET Premium Flush Front Assembly Faceplate AssemblyExclusions WarrantyWarranty Lifetime Conditions

IG35-LPG, IG35-ULPG, IG35-NG specifications

The Regency IG35-NG, IG35-ULPG, and IG35-LPG represent a trio of advanced heating solutions designed to cater to various fuel types while maintaining efficiency and user comfort. These units are ideal for modern residences and commercial spaces, showcasing technological advancements in the heating sector.

The IG35-NG operates on natural gas, offering an environmentally friendly solution with lower emissions compared to traditional heating methods. Its ability to provide consistent heat while being energy efficient makes it an attractive option for both new builds and retrofits. Featuring an automatic ignition system, the IG35-NG ensures quick and hassle-free operation, allowing users to enjoy immediate warmth.

For those in regions where propane is more accessible, the IG35-ULPG caters specifically to ultra-low propane gas environments. This model boasts similar performance metrics to the IG35-NG but is optimized for utilizing propane under lower pressure. The advanced burner technology employed in the IG35-ULPG tracks combustion efficiency and significantly reduces fuel consumption, making it both cost-effective and eco-friendly.

The IG35-LPG, on the other hand, is tailored for standard liquefied petroleum gas applications. Ideal for areas lacking natural gas infrastructure, this model ensures that users can still benefit from efficient heating solutions. The IG35-LPG incorporates sophisticated safety features, including flame failure detection and automatic shut-off systems. This ensures peace of mind for users by minimizing risks related to gas leaks and other potential hazards.

All three models share a sleek design, fitting seamlessly into various interior aesthetics. The compact size enhances installation flexibility, allowing these heaters to fit into spaces where traditional heating units may not suffice. Moreover, they come equipped with user-friendly controls that facilitate easy adjustments to temperature settings, ensuring optimal comfort during cold seasons.

In terms of energy efficiency, these heaters carry exceptional ratings, which may even qualify them for rebates and incentives in many regions. The advanced heat exchanger technology employed in these units allows for maximum heat transfer while minimizing waste, thus serving the dual purpose of reducing heating costs and environmental impact.

Overall, the Regency IG35 series presents a versatile and efficient lineup of heating solutions. With their modern technologies, user-centric features, and commitment to safety and efficiency, the IG35-NG, IG35-ULPG, and IG35-LPG represent the next generation of heating for both residential and commercial applications.