Teledyne 3000ZA-3X Introduction, Overview, Typical Applications, Main Features of the Analyzer

Page 13

Trace Oxygen Analyzer

Introduction

 

 

 

Introduction

1.1 Overview

The Teledyne Analytical Instruments Model 3000ZA Trace Oxygen Analyzer is a versatile microprocessor-based instrument for detecting oxygen at the parts-per-million (ppm) level in a variety of gases. This manual covers the Model 3000ZA General Purpose flush- panel and/or rack-mount units with CE mark. These units are for indoor use in a non-hazardous environment.

1.2 Typical Applications

A few typical applications of the Model 3000ZA are:

Monitoring inert gas blanketing

Air separation and liquefaction

Chemical reaction monitoring

Semiconductor manufacturing

Petrochemical process control

Quality assurance

Gas analysis certification.

1.3Main Features of the Analyzer

The Model 3000ZA Trace Oxygen Analyzer is sophisticated yet simple to use. The main features of the analyzer include:

A 2-line alphanumeric display screen, driven by microprocessor electronics that continuously prompts and informs the operator.

High resolution, accurate readings of oxygen content for low ppm levels. Large, bright, meter readout.

 

 

 

Teledyne Analytical Instruments

1

Image 13
Contents Model 3000ZA-3X 3000ZA-3X Specific Model Information Important Notice Safety Messages 3000ZA-3X Vii Table of Contents Testing the System Appendix MaintenanceModel 3000ZA Rear Panel Model 3000ZA Front PanelXii List of TablesIntroduction Main Features of the AnalyzerOverview Typical ApplicationsIntroduction 3000ZA-3X Model DesignationsModel 3000ZA Front Panel Front Panel Operator InterfaceData Entry Keys Function KeysDigital Meter Display Alphanumeric Interface ScreenRear Panel Equipment Interface Access DoorStandby Button Optional ∙ 50-Pin Equipment Interface PortIntroduction Operational TheoryZrO2 Sensor Principles of OperationOperational Theory 3000ZA-3X Sample SystemZirconium Oxide Sensor Application Notes Electronics and Signal ProcessingOperational Theory 3000ZA-3X Component Location Electronic Block Diagram Unpacking the Analyzer InstallationMounting the Analyzer Installation 3000ZA-3X Gas Connections Rear Panel ConnectionsInstallation3000ZA-3X Electrical Connections Zero in and Span in OptionalEquipment Interface Connector Pin Arrangement Analog Output Connections Threshold AlarmAlarm Relay Contact Pins System AlarmRemote Calibration Connections Range ID Relay Connections Remote Probe Connections 2.3 RS-232 Port FET Series ResistanceCommands via RS-232 Input Testing the System Installing the Zirconium Oxide SensorsOperation Style Conventions Using the Data Entry and Function ButtonsKeys Description Escape EnterAnalyze Screen Menu/Screen StructureSystem Menu Hierarchy of Available Functions Enter Password T a Password routineChange Password Enter New Password T aModel Routine Logout RoutineSelf-Test Routine Analog-Out Adjust RoutineFilter Routine 20mA Gain 20mA Limit False Track in Cal Yes Span Menu Auto-Calibration TimerChange Stream Span Sensor Span TimerSpan Value Span Auto Finish Span FinishSpan Begin Span Begin Begin Span?Zero Finish Zero MenuZero Value Zero Timer 7 min Zero TimerZero Begin Zero Begin Begin Zero?Alarm Active Alarms MenuAlarm Polarity AL-1 NON-LATCHING AL-1 20.00 ppm AL-2 ActiveAlarm Latching Alarm FailsafeAlarm Setpoint AL-1 80.00 ppmRange Select Range MenuRange Select Auto Range Setpoints Manual Range SelectRoutine Maintenance MaintenanceSensor Replacement Removing the SensorMaintenance 3000ZA-3X Sensor Block with Middle Sensor Installed Fuse ReplacementSelf-Test Result Display System Self Diagnostic TestRear Panel Removal Remove only those screws marked with an Major Internal ComponentsTroubleshooting CleaningTrace Oxygen Analyzer Maintenance Maintenance 3000ZA-3X Teledyne Analytical Instruments Appendix SpecificationsOperating Temperature 5-35 C Qty Part Number Description Recommended 2-Year Spare Parts List19-inch Relay Rack Panel Mount Drawing ListFlow Rate Recommendations Application NotesRestriction Devices BY-PASS Conversions