Teledyne operating instructions Model 3000ZA-3X

Page 1

Trace Oxygen Analyzer

OPERATING INSTRUCTIONS FOR

MODEL 3000ZA-3X

Trace Oxygen Analyzer

P/N M77579

11/29/11

DANGER

Toxic gases and or flammable liquids may be present in this monitoring system. Personal protective equipment may be required when servicing this instrument.

Hazardous voltages exist on certain components internally which may persist for a time even after the power is turned off and disconnected.

Only authorized personnel should conduct maintenance and/or servicing. Before conducting any maintenance or servicing, consult with authorized supervisor/manager.

 

 

Teledyne Analytical Instruments

i

Image 1
Contents Model 3000ZA-3X 3000ZA-3X Specific Model Information Important Notice Safety Messages 3000ZA-3X Vii Table of Contents Testing the System Appendix MaintenanceModel 3000ZA Rear Panel Model 3000ZA Front PanelXii List of TablesIntroduction Main Features of the AnalyzerOverview Typical ApplicationsIntroduction 3000ZA-3X Model DesignationsModel 3000ZA Front Panel Front Panel Operator InterfaceData Entry Keys Function KeysDigital Meter Display Alphanumeric Interface ScreenRear Panel Equipment Interface Access DoorStandby Button Optional ∙ 50-Pin Equipment Interface PortIntroduction Operational TheoryZrO2 Sensor Principles of OperationOperational Theory 3000ZA-3X Sample SystemZirconium Oxide Sensor Application Notes Electronics and Signal ProcessingOperational Theory 3000ZA-3X Component Location Electronic Block Diagram Unpacking the Analyzer InstallationMounting the Analyzer Installation 3000ZA-3X Gas Connections Rear Panel ConnectionsInstallation3000ZA-3X Electrical Connections Zero in and Span in OptionalEquipment Interface Connector Pin Arrangement Analog Output Connections Threshold AlarmAlarm Relay Contact Pins System AlarmRemote Calibration Connections Range ID Relay Connections Remote Probe Connections 2.3 RS-232 Port FET Series ResistanceCommands via RS-232 Input Testing the System Installing the Zirconium Oxide SensorsOperation Style Conventions Using the Data Entry and Function ButtonsKeys Description Escape EnterAnalyze Screen Menu/Screen StructureSystem Menu Hierarchy of Available Functions Enter Password T a Password routineChange Password Enter New Password T aModel Routine Logout RoutineSelf-Test Routine Analog-Out Adjust RoutineFilter Routine 20mA Gain 20mA Limit False Track in Cal Yes Span Menu Auto-Calibration TimerChange Stream Span Sensor Span TimerSpan Value Span Auto Finish Span FinishSpan Begin Span Begin Begin Span?Zero Finish Zero MenuZero Value Zero Timer 7 min Zero TimerZero Begin Zero Begin Begin Zero?Alarm Active Alarms MenuAlarm Polarity AL-1 NON-LATCHING AL-1 20.00 ppm AL-2 ActiveAlarm Latching Alarm FailsafeAlarm Setpoint AL-1 80.00 ppmRange Select Range MenuRange Select Auto Range Setpoints Manual Range SelectRoutine Maintenance MaintenanceSensor Replacement Removing the SensorMaintenance 3000ZA-3X Sensor Block with Middle Sensor Installed Fuse ReplacementSelf-Test Result Display System Self Diagnostic TestRear Panel Removal Remove only those screws marked with an Major Internal ComponentsTroubleshooting CleaningTrace Oxygen Analyzer Maintenance Maintenance 3000ZA-3X Teledyne Analytical Instruments Appendix SpecificationsOperating Temperature 5-35 C Qty Part Number Description Recommended 2-Year Spare Parts List19-inch Relay Rack Panel Mount Drawing ListFlow Rate Recommendations Application NotesRestriction Devices BY-PASS Conversions