3000ZA-3X

 

 

 

4.2 Using the Data Entry and Function Buttons

4.2.1 Style Conventions

The following typeface conventions are used when referring to screen names, key presses and screen readout:

Screens:

Arial 12 pt. type in capital letters.

 

Example: ANALYZE or MAIN

 

screen or menu.

Key presses:

<key> The particular keystroke to

 

enter is placed between < and >.

 

Example: <ENTER> or

 

<ESCAPE> or <UP> or

 

<DOWN>.

 

Only when the keystroke is to be

 

entered will it be placed between

 

the brackets. If discussing a

 

particular key it will be typed

 

using all caps. Example: this is the

 

ENTER key.

Screen Modes:

Times New Roman 12 pt. italic.

 

Example: Analysis Mode or Setup

 

Mode.

Screen Readout:

Arial Narrow, 12 pt bold.

 

Example: AUTOCAL or Zero in 12

 

days.

4.2.2 Keys Description

Note: All menus time out after 45 seconds elapse with no button presses, the analyzer returns to the ANALYSIS SCREEN, if parameters have been altered but not saved (with the ENTER key), the alterations are lost.

Navigation and Data Entry is possible using the UP and DOWN KEYS, the ENTER key, the ESCAPE key and the 7 special function keys (ANALYZE, SYSTEM, SPAN, ZERO, ALARMS, RANGE, and

Teledyne Analytical Instruments

28

Image 40
Contents Model 3000ZA-3X 3000ZA-3X Specific Model Information Important Notice Safety Messages 3000ZA-3X Vii Table of Contents Testing the System Maintenance AppendixModel 3000ZA Front Panel Model 3000ZA Rear PanelList of Tables XiiMain Features of the Analyzer IntroductionOverview Typical ApplicationsModel Designations Introduction 3000ZA-3XFront Panel Operator Interface Model 3000ZA Front PanelFunction Keys Data Entry KeysDigital Meter Display Alphanumeric Interface ScreenRear Panel Equipment Interface Access DoorStandby Button ∙ 50-Pin Equipment Interface Port OptionalOperational Theory IntroductionZrO2 Sensor Principles of OperationSample System Operational Theory 3000ZA-3XElectronics and Signal Processing Zirconium Oxide Sensor Application NotesOperational Theory 3000ZA-3X Component Location Electronic Block Diagram Unpacking the Analyzer InstallationMounting the Analyzer Installation 3000ZA-3X Rear Panel Connections Gas ConnectionsInstallation3000ZA-3X Zero in and Span in Optional Electrical ConnectionsEquipment Interface Connector Pin Arrangement Threshold Alarm Analog Output ConnectionsSystem Alarm Alarm Relay Contact PinsRemote Calibration Connections Range ID Relay Connections Remote Probe Connections FET Series Resistance 2.3 RS-232 PortCommands via RS-232 Input Installing the Zirconium Oxide Sensors Testing the SystemOperation Style Conventions Using the Data Entry and Function ButtonsKeys Description Enter EscapeAnalyze Screen Menu/Screen StructureSystem Menu Hierarchy of Available Functions Password routine Enter Password T aChange Password Enter New Password T aLogout Routine Model RoutineSelf-Test Routine Analog-Out Adjust RoutineFilter Routine 20mA Gain 20mA Limit False Track in Cal Yes Span Menu Auto-Calibration TimerChange Stream Span Sensor Span TimerSpan Value Span Finish Span Auto FinishSpan Begin Span Begin Begin Span?Zero Finish Zero MenuZero Value Zero Timer Zero Timer 7 minZero Begin Zero Begin Begin Zero?Alarms Menu Alarm ActiveAlarm Polarity AL-1 NON-LATCHING AL-1 20.00 ppm AL-2 ActiveAlarm Failsafe Alarm LatchingAlarm Setpoint AL-1 80.00 ppmRange Select Range MenuRange Select Auto Manual Range Select Range SetpointsMaintenance Routine MaintenanceSensor Replacement Removing the SensorMaintenance 3000ZA-3X Fuse Replacement Sensor Block with Middle Sensor InstalledSystem Self Diagnostic Test Self-Test Result DisplayMajor Internal Components Rear Panel Removal Remove only those screws marked with anCleaning TroubleshootingTrace Oxygen Analyzer Maintenance Maintenance 3000ZA-3X Teledyne Analytical Instruments Specifications AppendixOperating Temperature 5-35 C Recommended 2-Year Spare Parts List Qty Part Number DescriptionDrawing List 19-inch Relay Rack Panel MountApplication Notes Flow Rate RecommendationsRestriction Devices BY-PASS Conversions