Trace Oxygen Analyzer

This is a general purpose instrument designed for use in a non-hazardous area. It is the customer's responsibility to ensure safety especially when combustible gases are being analyzed since the potential of gas leaks always exist.

The customer should ensure that the principles of operation of this equipment is well understood by the user. Misuse of this product in any manner, tampering with its components, or unauthorized substitution of any component may adversely affect the safety of this instrument.

Since the use of this instrument is beyond the control of Teledyne Analytical Instruments, no responsibility by Teledyne Analytical Instruments, its affiliates, and agents for damage or injury from misuse or neglect of this equipment is implied or assumed.

 

 

 

Teledyne Analytical Instruments

vii

Image 7
Contents Model 3000ZA-3X 3000ZA-3X Specific Model Information Important Notice Safety Messages 3000ZA-3X Vii Table of Contents Testing the System Appendix MaintenanceModel 3000ZA Rear Panel Model 3000ZA Front PanelXii List of TablesTypical Applications Main Features of the AnalyzerIntroduction OverviewIntroduction 3000ZA-3X Model DesignationsModel 3000ZA Front Panel Front Panel Operator InterfaceAlphanumeric Interface Screen Function KeysData Entry Keys Digital Meter DisplayRear Panel Equipment Interface Access DoorStandby Button Optional ∙ 50-Pin Equipment Interface PortPrinciples of Operation Operational TheoryIntroduction ZrO2 SensorOperational Theory 3000ZA-3X Sample SystemZirconium Oxide Sensor Application Notes Electronics and Signal ProcessingOperational Theory 3000ZA-3X Component Location Electronic Block Diagram Unpacking the Analyzer InstallationMounting the Analyzer Installation 3000ZA-3X Gas Connections Rear Panel ConnectionsInstallation3000ZA-3X Electrical Connections Zero in and Span in OptionalEquipment Interface Connector Pin Arrangement Analog Output Connections Threshold AlarmAlarm Relay Contact Pins System AlarmRemote Calibration Connections Range ID Relay Connections Remote Probe Connections 2.3 RS-232 Port FET Series ResistanceCommands via RS-232 Input Testing the System Installing the Zirconium Oxide SensorsOperation Style Conventions Using the Data Entry and Function ButtonsKeys Description Escape EnterAnalyze Screen Menu/Screen StructureSystem Menu Hierarchy of Available Functions Enter New Password T a Password routineEnter Password T a Change PasswordModel Routine Logout RoutineSelf-Test Routine Analog-Out Adjust RoutineFilter Routine 20mA Gain 20mA Limit False Track in Cal Yes Span Menu Auto-Calibration TimerChange Stream Span Sensor Span TimerSpan Value Span Begin Begin Span? Span FinishSpan Auto Finish Span BeginZero Finish Zero MenuZero Value Zero Begin Begin Zero? Zero TimerZero Timer 7 min Zero BeginAL-1 NON-LATCHING AL-1 20.00 ppm AL-2 Active Alarms MenuAlarm Active Alarm PolarityAL-1 80.00 ppm Alarm FailsafeAlarm Latching Alarm SetpointRange Select Range MenuRange Select Auto Range Setpoints Manual Range SelectRemoving the Sensor MaintenanceRoutine Maintenance Sensor ReplacementMaintenance 3000ZA-3X Sensor Block with Middle Sensor Installed Fuse ReplacementSelf-Test Result Display System Self Diagnostic TestRear Panel Removal Remove only those screws marked with an Major Internal ComponentsTroubleshooting CleaningTrace Oxygen Analyzer Maintenance Maintenance 3000ZA-3X Teledyne Analytical Instruments Appendix SpecificationsOperating Temperature 5-35 C Qty Part Number Description Recommended 2-Year Spare Parts List19-inch Relay Rack Panel Mount Drawing ListFlow Rate Recommendations Application NotesRestriction Devices BY-PASS Conversions