Using the Unit

Components of the Product

Before using the unit, make sure that no accessories are missing and that the unit and accessories are not damaged. If an accessory is missing or there is damage, please contact OMRON HEALTHCARE Customer Service.

Main unit

Standard accessories

AC adapter

GS CUFF L and M

Instruction Manual

Optional Accessories

Wall mount kit

WMKIT-1300

(HXA-WMKIT-1300)

Battery pack

BAT-2000 (HXA-BAT-2000)

AC adapter

AC-1300Z (60120H1040SW-Z)

10

Image 12
Contents HBP-1300 Page Introduction Intended UseExemptions General Information Setup Usage warnings and cautionsBefore use / during use Page Cleaning Maintenance and inspectionOptional rechargeable battery Non-Invasive Blood Pressure Nibp measurement For cleaning, see Using the Unit Optional AccessoriesMain unit Standard accessories Components of the ProductFeatures of the Product Key features, benefits, lookCuff Hose 3.5 m Cuff Hose 1.5mFeatures / Functions of Unit Meaning of the SymbolsFront and back of unit Using the Unit Only when the optional battery is installedLCD Display Installing the Optional Battery Pack Battery lifeLow battery Auto Power OffConnecting the AC Adapter Battery chargingBattery level AC powerSystem Settings Menu ModePress the Mode button Press the or button to change the settingUtility Mode Press the or button to change the auto power off settingCheck the Pressure Accuracy ExampleNon-Invasive Blood Pressure Nibp Measurement Non-Invasive Pressure Measurement PrinciplesConnecting the cuff Available as an optional accessoryCuff Selection and Connection Selecting the cuffAlign the artery mark Index Artery with the brachial artery Measurement results are displayed Blood pressure measurement is performed onceFailure Taking the Measurement in Auscultation Mode Irregular pulse wave detection functionBody movement detection function Use a stethoscope to perform measurementStopping the Measurement Displaying Last ReadingIrregular pulse wave icon Appears Maintenance Maintenance Inspection and Safety ManagementDevice Maintenance Accessory CareBefore turning on the power When turning on the powerAfter turning on the power Check before UseTroubleshooting Stethoscope Abnormal measurement valueMeasurement value is questionable List of Error Codes Error Priority Description Points to checkOther problems Error Priority Cause Solution CodeDisposal DescriptionLimited Warranty Call toll freeSpecifications Factory Default SettingsSpecifications BackupPower supply Environmental ConditionsNon-Invasive Blood Pressure Nibp Manufacturers Declaration Electromagnetic Immunity IEC60601-1-2Emission Test Compliance Electromagnetic Environment IEC60601-1-2 Electromagnetic Test level Recommend separation distancePage Recommended Separation Distances Separation distance according to frequency of transmitterPage For Customer Service Call Toll Free Distributed byWest Field Court, Lake Forest, IL 60045, USA Made in China
Related manuals
Manual 38 pages 5.6 Kb