Omron HBP-1300 specifications Before use / during use

Page 6

Before use / during use

Warning

The unit complies with the EMC standard (IEC60601-1-2). As such, it can be used simultaneously with multiple medical instruments. However, if instruments that generate noise such as an electric scalpel or a microwave therapy device are near the unit, check the operation of the unit during and after use of these instruments.

If an error occurs or a measurement result is questionable, check the vital signs of the patient by auscultation or palpation. Avoid relying solely on the measurement results of the unit when judging the patient's condition.

Only trained healthcare providers should use this device. Do not allow patients to operate this device.

Properly connect the connectors and AC adapter cable.

Do not place objects or liquids on top of this unit.

Check the following before using the unit:

-Make sure the AC adapter cable is not damaged (wires are not exposed or broken), and the connections are firm.

For the AC adapter connected to the unit, supplies, and optional devices, use only the standard accessories or OMRON-specified products.

Do not use in a location with moisture, or a location where water may splash on the unit. This unit is intended for use in a physician's office.

Do not use the unit if it emits smoke, an abnormal odor, or abnormal noise.

Do not bring cellular telephones or transceivers into the room where the unit is installed or being used.

Do not connect multiple monitors to the same patient.

Do not connect the unit to a power outlet that is controlled by a wall switch.

4

Image 6
Contents HBP-1300 Page Introduction Intended UseExemptions General Information Setup Usage warnings and cautionsBefore use / during use Page Cleaning Maintenance and inspectionOptional rechargeable battery Non-Invasive Blood Pressure Nibp measurement For cleaning, see Main unit Standard accessories Using the UnitOptional Accessories Components of the ProductCuff Hose 3.5 m Features of the ProductKey features, benefits, look Cuff Hose 1.5mFeatures / Functions of Unit Meaning of the SymbolsFront and back of unit Using the Unit Only when the optional battery is installedLCD Display Low battery Installing the Optional Battery PackBattery life Auto Power OffBattery level Connecting the AC AdapterBattery charging AC powerPress the Mode button System SettingsMenu Mode Press the or button to change the settingCheck the Pressure Accuracy Utility ModePress the or button to change the auto power off setting ExampleNon-Invasive Blood Pressure Nibp Measurement Non-Invasive Pressure Measurement PrinciplesCuff Selection and Connection Connecting the cuffAvailable as an optional accessory Selecting the cuffAlign the artery mark Index Artery with the brachial artery Measurement results are displayed Blood pressure measurement is performed onceFailure Body movement detection function Taking the Measurement in Auscultation ModeIrregular pulse wave detection function Use a stethoscope to perform measurementStopping the Measurement Displaying Last ReadingIrregular pulse wave icon Appears Device Maintenance MaintenanceMaintenance Inspection and Safety Management Accessory CareAfter turning on the power Before turning on the powerWhen turning on the power Check before UseTroubleshooting Stethoscope Abnormal measurement valueMeasurement value is questionable List of Error Codes Error Priority Description Points to checkDisposal Other problemsError Priority Cause Solution Code DescriptionLimited Warranty Call toll freeSpecifications SpecificationsFactory Default Settings BackupPower supply Environmental ConditionsNon-Invasive Blood Pressure Nibp Manufacturers Declaration Electromagnetic Immunity IEC60601-1-2Emission Test Compliance Electromagnetic Environment IEC60601-1-2 Electromagnetic Test level Recommend separation distancePage Recommended Separation Distances Separation distance according to frequency of transmitterPage For Customer Service Call Toll Free Distributed byWest Field Court, Lake Forest, IL 60045, USA Made in China