Omron HBP-1300 Features / Functions of Unit, Front and back of unit, Meaning of the Symbols

Page 14

Features / Functions of Unit

Front and back of unit

2

4

6

5

3

1

7

1

2

3

 

Power ON / Measure blood pressure

 

Press when the power is off to turn on the power and start

[START/STOP] button

blood pressure measurement. During inflation or

(Power ON/OFF)

measurement, press to stop.

 

Power OFF

 

Hold down at least 3 seconds to turn off the power.

 

Press to enter "Menu Mode" and configure various settings.

[MODE] button

If held down at least 3 seconds when a measurement result

is displayed, the measured data is cleared without being

 

 

stored in memory.

 

Displays the system settings (page 16) and the last reading

[ ] [ ] button

(page 23). When using "Auscultation Mode", inflates and

 

deflates the cuff.

4

Alarm lamp

Lights up or flashes when an alarm occurs (page 28).

 

 

 

5

NIBP connector

Connects the cuff tube.

 

 

 

6

DC jack

Connects the AC adapter.

 

 

 

7

Battery cover

Open to install or replace the battery.

 

 

 

Meaning of the Symbols

Symbol Description

Symbol Description

This shows the type BF device.

Refer to manual.

 

 

MEDICAL EQUIPMENT

 

WITH RESPECT TO ELECTRICAL

 

SHOCK, FIRE AND MECHANICAL

 

HAZARDS ONLY IN ACCORDANCE

 

WITH UL60601-1 and CAN/CSA C22.2

 

No.601.1

 

 

 

12

Image 14
Contents HBP-1300 Page Exemptions IntroductionIntended Use General Information Setup Usage warnings and cautionsBefore use / during use Page Cleaning Maintenance and inspectionOptional rechargeable battery Non-Invasive Blood Pressure Nibp measurement For cleaning, see Main unit Standard accessories Using the UnitOptional Accessories Components of the ProductCuff Hose 3.5 m Features of the ProductKey features, benefits, look Cuff Hose 1.5mFront and back of unit Features / Functions of UnitMeaning of the Symbols LCD Display Using the UnitOnly when the optional battery is installed Low battery Installing the Optional Battery PackBattery life Auto Power OffBattery level Connecting the AC AdapterBattery charging AC powerPress the Mode button System SettingsMenu Mode Press the or button to change the settingCheck the Pressure Accuracy Utility ModePress the or button to change the auto power off setting ExampleNon-Invasive Blood Pressure Nibp Measurement Non-Invasive Pressure Measurement PrinciplesCuff Selection and Connection Connecting the cuffAvailable as an optional accessory Selecting the cuffAlign the artery mark Index Artery with the brachial artery Failure Measurement results are displayedBlood pressure measurement is performed once Body movement detection function Taking the Measurement in Auscultation ModeIrregular pulse wave detection function Use a stethoscope to perform measurementIrregular pulse wave icon Appears Stopping the MeasurementDisplaying Last Reading Device Maintenance MaintenanceMaintenance Inspection and Safety Management Accessory CareAfter turning on the power Before turning on the powerWhen turning on the power Check before UseTroubleshooting Measurement value is questionable StethoscopeAbnormal measurement value List of Error Codes Error Priority Description Points to checkDisposal Other problemsError Priority Cause Solution Code DescriptionLimited Warranty Call toll freeSpecifications SpecificationsFactory Default Settings BackupNon-Invasive Blood Pressure Nibp Power supplyEnvironmental Conditions Emission Test Compliance Electromagnetic Environment Manufacturers DeclarationElectromagnetic Immunity IEC60601-1-2 IEC60601-1-2 Electromagnetic Test level Recommend separation distancePage Recommended Separation Distances Separation distance according to frequency of transmitterPage West Field Court, Lake Forest, IL 60045, USA Made in China For Customer Service Call Toll FreeDistributed by