Warnings and cautions for safe measurement

Optional rechargeable battery

Warning

If battery fluid comes in contact with the eye, immediately flush with copious amounts of water. Do not rub. Seek medical attention immediately.

Do not use the optional battery pack in any other device besides this unit. Do not throw into flame, disassemble, or heat.

Always disconnect the AC adapter from the unit before removing or installing a battery.

If the unit will not be used for a month or longer, remove the battery from the unit and store. Charge the battery once every 6 months. (Storage conditions for the battery are a temperature of -20 to 30°C (-4 to 86°F) and a humidity of 65 ±20%.)

Before use, always charge the battery.

Do not attempt to disassemble or modify the battery.

Do not apply pressure to and deform the battery. Do not throw, pound, drop, bend, or hit the battery.

The battery has positive/negative polarity. If the battery does not connect well to the unit, do not forcibly connect it.

Do not connect the positive and negative terminals of the battery with a wire or other metal object. Do not carry or store a battery with metal necklaces, hairpins, or other metal objects.

Use only the specified type of battery.

Caution

Do not touch the positive and negative terminals of the optional battery pack with a wire or other metal object. If battery fluid comes into contact with the skin or clothes, immediately rinse with water.

Introduction

7

Image 9
Contents HBP-1300 Page Introduction Intended UseExemptions General Information Usage warnings and cautions SetupBefore use / during use Page Maintenance and inspection CleaningOptional rechargeable battery Non-Invasive Blood Pressure Nibp measurement For cleaning, see Optional Accessories Using the UnitMain unit Standard accessories Components of the ProductKey features, benefits, look Features of the ProductCuff Hose 3.5 m Cuff Hose 1.5mFeatures / Functions of Unit Meaning of the SymbolsFront and back of unit Using the Unit Only when the optional battery is installedLCD Display Battery life Installing the Optional Battery PackLow battery Auto Power OffBattery charging Connecting the AC AdapterBattery level AC powerMenu Mode System SettingsPress the Mode button Press the or button to change the settingPress the or button to change the auto power off setting Utility ModeCheck the Pressure Accuracy ExampleNon-Invasive Pressure Measurement Principles Non-Invasive Blood Pressure Nibp MeasurementAvailable as an optional accessory Connecting the cuffCuff Selection and Connection Selecting the cuffAlign the artery mark Index Artery with the brachial artery Measurement results are displayed Blood pressure measurement is performed onceFailure Irregular pulse wave detection function Taking the Measurement in Auscultation ModeBody movement detection function Use a stethoscope to perform measurementStopping the Measurement Displaying Last ReadingIrregular pulse wave icon Appears Maintenance Inspection and Safety Management MaintenanceDevice Maintenance Accessory CareWhen turning on the power Before turning on the powerAfter turning on the power Check before UseTroubleshooting Stethoscope Abnormal measurement valueMeasurement value is questionable Error Priority Description Points to check List of Error CodesError Priority Cause Solution Code Other problemsDisposal DescriptionCall toll free Limited WarrantyFactory Default Settings SpecificationsSpecifications BackupPower supply Environmental ConditionsNon-Invasive Blood Pressure Nibp Manufacturers Declaration Electromagnetic Immunity IEC60601-1-2Emission Test Compliance Electromagnetic Environment Recommend separation distance IEC60601-1-2 Electromagnetic Test levelPage Separation distance according to frequency of transmitter Recommended Separation DistancesPage For Customer Service Call Toll Free Distributed byWest Field Court, Lake Forest, IL 60045, USA Made in China