Omron HBP-1300 specifications Specifications, Factory Default Settings, Main unit, Backup

Page 33

Specifications

Factory Default Settings

Factory default settings and backup are as shown below.

Backup

: Setting is retained even if the power is interrupted.

: Reverts to factory default setting if the power is turned off.

Setting Pressure Value

Settings

Factory Setting

Backup

Initial Inflation Pressure Value

AUTO, 220, 250, 280

AUTO

 

 

 

 

 

Auscultation Mode

ON, OFF

OFF

 

 

 

 

 

Auto Power Off

5 min, 10 min

5 min

 

 

 

 

 

Specifications

Main unit

Measurement Parameter

NIBP

 

 

Dimension

Main unit: 4.84 x 7.91 x 3.90 (inch) 123 x 201 x 99 (mm) (W x H x D)

 

AC adapter: 1.81 x 2.60 x 1.46 (inch) 46 x 66 x 37 (mm) (W x H x D)

 

Battery: 2.13 x 1.71 x 0.61 (inch) 54 x 43.5 x 15.4 (mm) (W x H x D)

 

 

Weight

Main unit: Approx. 18.34 oz (0.52 kg) (not including accessories and options)

 

AC adapter: Approx. 7.05 oz (0.2 kg)

 

Battery: Approx. 3.53 oz (0.1 kg) (optional accessory)

 

 

Display

7 segment LCD

 

 

UL Classfield

WITH RESPECT TO ELECTRICAL SHOCK, FIRE AND MECHANICAL

 

HAZARDS ONLY.

 

 

Safety Standards

IEC 60601-1:1988+A1:1993+A2:1995

 

UL60601-1:First Edition

 

Medical electrical equipment-Part1:General requirements for safety

 

 

Protection Class

Class II

 

Internal powered equipment

 

 

Degree of Protection

Type BF

 

 

 

MDD Classification

Class II a

 

 

Specifications

31

Image 33
Contents HBP-1300 Page Introduction Intended UseExemptions General Information Usage warnings and cautions SetupBefore use / during use Page Maintenance and inspection CleaningOptional rechargeable battery Non-Invasive Blood Pressure Nibp measurement For cleaning, see Optional Accessories Using the UnitMain unit Standard accessories Components of the ProductKey features, benefits, look Features of the ProductCuff Hose 3.5 m Cuff Hose 1.5mFeatures / Functions of Unit Meaning of the SymbolsFront and back of unit Using the Unit Only when the optional battery is installedLCD Display Battery life Installing the Optional Battery PackLow battery Auto Power OffBattery charging Connecting the AC AdapterBattery level AC powerMenu Mode System SettingsPress the Mode button Press the or button to change the settingPress the or button to change the auto power off setting Utility ModeCheck the Pressure Accuracy ExampleNon-Invasive Pressure Measurement Principles Non-Invasive Blood Pressure Nibp MeasurementAvailable as an optional accessory Connecting the cuffCuff Selection and Connection Selecting the cuffAlign the artery mark Index Artery with the brachial artery Measurement results are displayed Blood pressure measurement is performed onceFailure Irregular pulse wave detection function Taking the Measurement in Auscultation ModeBody movement detection function Use a stethoscope to perform measurementStopping the Measurement Displaying Last ReadingIrregular pulse wave icon Appears Maintenance Inspection and Safety Management MaintenanceDevice Maintenance Accessory CareWhen turning on the power Before turning on the powerAfter turning on the power Check before UseTroubleshooting Stethoscope Abnormal measurement valueMeasurement value is questionable Error Priority Description Points to check List of Error CodesError Priority Cause Solution Code Other problemsDisposal DescriptionCall toll free Limited WarrantyFactory Default Settings SpecificationsSpecifications BackupPower supply Environmental ConditionsNon-Invasive Blood Pressure Nibp Manufacturers Declaration Electromagnetic Immunity IEC60601-1-2Emission Test Compliance Electromagnetic Environment Recommend separation distance IEC60601-1-2 Electromagnetic Test levelPage Separation distance according to frequency of transmitter Recommended Separation DistancesPage For Customer Service Call Toll Free Distributed byWest Field Court, Lake Forest, IL 60045, USA Made in China