Position Calibration

PELCO EXSITE IPSXM

LANGUAGE

ENGLISH

UNIT INVERSION

OFF

<SYSTEM INFORMATION>

 

<DISPLAY SETUP>

 

<UNIT SETTINGS>

 

<POSITION CALIBRATION>

 

RESET CAMERA

 

CYCLE CAMERA POWER

 

REBOOT SYSTEM

 

EXIT

 

 

 

 

 

 

 

 

 

 

 

POSITION CALIBRATION

*** PRESET NOT DEFINED ***

<EDIT PRESET SCENE>

<CLEAR CALIBRATION PRESET> <RECAL USING CAL PRESET>

BACK

EXIT

REFERENCE INFORMATION

AZIMUTH

ELEVATION

ZOOM

Position calibration sets the preset reference point for all automatic positioning system movements. Before programming presets, patterns, zones, labels, and window blanking, program and document the position calibration point. The purpose of the calibration point is to restore all programmed settings quickly in the event the unit is replaced or refurbished.

The position calibration point should be an easily identifiable point of reference. Best practice suggests it be associated with a prominent landmark in the most common preset position.

To program the calibration preset:

1.Use the joystick to position the cursor beside POSITION CALIBRATION.

2.Press Iris Open. The Position Calibration menu appears on the monitor.

3.Use the joystick to position the cursor beside EDIT PRESET SCENE.

4.Press Iris Open.

5.Follow the directions displayed on the monitor.

Once the calibration preset is programmed, the system should not have to be recalibrated unless the unit is serviced or moved.

To recalculate the calibration preset:

1.Use the joystick to position the cursor beside POSITION CALIBRATION.

2.Press Iris Open. The Position Calibration menu appears on the monitor.

3.Use the joystick to position the cursor beside RECAL USING CAL PRESET.

4.Press Iris Open.

5.Follow the directions displayed on the monitor.

To clear the calibration preset:

1.Use the joystick to position the cursor beside POSITION CALIBRATION.

2.Press Iris Open. The Position Calibration menu appears on the monitor.

3.Use the joystick to position the cursor beside CLEAR CALIBRATION PRESET.

4.Press Iris Open.

5.Follow the directions displayed on the monitor.

C1300M-C (11/08)

43

Image 43
Contents ExSite Series Explosionproof Positioning System Page Contents Specifications Radio and Television Interference Regulatory NoticesGetting Started Configure DoneWelcome ModelsHow to Operate Your System KBD200A/KBD300A Direct Mode only Accessing Main Menu PresetKBD4000/KBD4002 Genex Multiplexer Quick Start Guide System Setup C1300M-C 11/08 Language Unit Inversion OFF default Use for normal installations refer to FigureSystem Information Display Setup Label Positions Camera Unit SettingsDark IR CUT Filter 23X DAY/NIGHT CameraShutter Speed Advanced Camera SettingsAGC Limit Gain Auto IrisAuto Sharpness Auto White BalanceNormal Backlight Compensation BLCVideo Level Wide Dynamic Range 23X DAY/NIGHT CameraAmount of zoom There are two proportional pan modes On defaultMotion Proportional PANPark Time Image is never frozen Preset Freeze FrameThere are three preset freeze frame settings Scan SpeedLimit stop is reached Limit StopsManual ScanAzimuth Zero Power UP Action Power UPNone Line Sync Phase settings range from 0-359 degreesSystem synchronizes to an internal clock Presets Edit Detection Areas 23X DAY/NIGHT Camera Enable Motion Detection 23X DAY/NIGHT CameraTriggers a command to AUX Activate AUX Command 23X DAY/NIGHT CameraAUX Time 23X DAY/NIGHT Camera Patterns Zones To set a window blanking area Window BlankingBlank ALL ABOVE/BLANK ALL below Available OFF default No blankingReverse Clear WindowSequence AlarmsReset Delay ResumeMEDIUM/LOW Normally open Wiper Dwell Wiper ModeWiper Wiper ControlSET Washer Sequence Latching When the dwell time is finishedAUX Received from the controllerClear Password Position Calibration Reboot System Reset, Cycle Power, RebootReset Camera Cycle Camera PowerUpload Icon Software/Language File UploadPAL SpecificationsNTSC, PAL NtscProduct Warranty and Return Information