Pelco C1300M-C (11/08) manual Park Time

Page 22

PELCO EXSITE IPSXM

LANGUAGE

ENGLISH

 

UNIT INVERSION

OFF

 

<SYSTEM INFORMATION>

 

 

<DISPLAY SETUP>

 

 

<UNIT SETTINGS>

 

 

<POSITION CALIBRATION>

 

 

RESET CAMERA

 

 

CYCLE CAMERA POWER

 

 

REBOOT SYSTEM

 

 

EXIT

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT SETTINGS

 

 

 

 

 

<CAMERA>

 

 

<MOTION>

 

 

<POWER UP>

 

 

<LINE SYNC>

 

 

<PRESETS>

 

 

<PATTERNS>

 

 

<ZONES>

 

 

<WINDOW BLANKING>

 

 

<ALARMS>

 

 

<WIPER>

 

 

<AUX>

 

 

<CLEAR>

 

 

<PASSWORD>

 

 

BACK

 

 

EXIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MOTION

 

 

 

 

 

PROPORTIONAL PAN

ON

 

PARK TIME (MINUTES)

0

 

PARK ACTION

NONE

 

SCAN SPEED (DEG/S)

25

 

PRESET FREEZE FRAME

AUTO

 

LIMIT STOPS

ON

 

<SET MANUAL STOPS>

 

 

<CLEAR MANUAL STOPS>

 

 

<SET SCAN STOPS>

 

 

<CLEAR SCAN STOPS>

 

 

<SET AZIMUTH ZERO>

 

 

<CLEAR AZIMUTH ZERO>

 

 

BACK

 

 

EXIT

 

 

REFERENCE INFORMATION

 

 

MANUAL LIMITS SET

NO

 

SCAN LIMITS SET

NO

 

 

 

 

 

 

 

PARK TIME

This feature allows the system to begin a specified operation (scan, preset, or pattern) after a programmed time of inactivity.

Park time can be programmed from 1 minute to 720 minutes (12 hours), or set to zero, which disables this feature. The default setting is zero.

Park Action

This feature will define the activity when the system parks. The following settings are available:

NONE (default)

No action.

AUTO SCAN

The system starts auto scan operation.

RANDOM SCAN

The system starts random scan operation.

FRAME SCAN

The system starts frame scan operation.

PRESET 1

The system goes to preset 1.

PRESET 8

The system goes to preset 8.

PATTERN 1

The system runs pattern 1.

PATTERN 2

The system runs pattern 2.

PATTERN 3

The system runs pattern 3.

PATTERN 4

The system runs pattern 4.

22

C1300M-C (11/08)

Image 22
Contents ExSite Series Explosionproof Positioning System Page Contents Specifications Regulatory Notices Radio and Television InterferenceModels Configure DoneWelcome Getting StartedHow to Operate Your System KBD200A/KBD300A Direct Mode only Accessing Main Menu PresetKBD4000/KBD4002 Genex Multiplexer Quick Start Guide System Setup C1300M-C 11/08 Language OFF default Use for normal installations refer to Figure Unit InversionSystem Information Display Setup Label Positions Unit Settings CameraIR CUT Filter 23X DAY/NIGHT Camera DarkShutter Speed Advanced Camera SettingsAGC Limit Auto White Balance Auto IrisAuto Sharpness GainWide Dynamic Range 23X DAY/NIGHT Camera Backlight Compensation BLCVideo Level NormalProportional PAN There are two proportional pan modes On defaultMotion Amount of zoomPark Time Scan Speed Preset Freeze FrameThere are three preset freeze frame settings Image is never frozenScan Limit StopsManual Limit stop is reachedAzimuth Zero Power UP Action Power UPNone Line Sync Phase settings range from 0-359 degreesSystem synchronizes to an internal clock Presets Enable Motion Detection 23X DAY/NIGHT Camera Edit Detection Areas 23X DAY/NIGHT CameraTriggers a command to AUX Activate AUX Command 23X DAY/NIGHT CameraAUX Time 23X DAY/NIGHT Camera Patterns Zones Window Blanking To set a window blanking areaClear Window Available OFF default No blankingReverse Blank ALL ABOVE/BLANK ALL belowResume AlarmsReset Delay SequenceMEDIUM/LOW Normally open Wiper Control Wiper ModeWiper Wiper DwellSET Washer Sequence Received from the controller When the dwell time is finishedAUX LatchingClear Password Position Calibration Cycle Camera Power Reset, Cycle Power, RebootReset Camera Reboot SystemSoftware/Language File Upload Upload IconNtsc SpecificationsNTSC, PAL PALProduct Warranty and Return Information