Lifescan Blood Glucose Monitor System manual Symbol appears on the display

Page 37

2. The

symbol appears on the display

by itself. This means that the batteries will not provide enough power for a test. You must change the batteries.

To replace the batteries, make sure that the meter is turned off. Turn the meter over and locate the battery compartment.

1. Press down with both thumbs on each side of the battery cover’s imprinted arrow. Then slide the battery cover away in the direction of the arrow.

2. Remove the old batteries. Insert two 1.5 V #357 silver oxide batteries, making sure the positive “+” side of each battery is facing up in the meter.

3. Place the three tabs of the battery cover into the three slots in the meter. Push the battery cover upward in the direction of its imprint- ed arrow to align the sides of the battery cover with the meter. Slide the battery cover down into place until it clicks.

Note:

Replacing the batteries does not affect the meter’s memory (previous test results stored in memory). However, the date and time settings may need to be updated.

The first time you turn on the meter after replacing the batteries, it will go into the set- ting mode. At this time, you should update the date and time settings.

27

Image 37
Contents Owner’s Booklet Page Owner’s Booklet 5.8 Dear PocketScan System Owner Page Important Information Table of Contents Using the Meter Memory Viii Getting Started PocketScan Blood Glucose Meter Test Port Target Area PocketScan Test StripsImportant Test Strip Information Coding the Meter Checking the DisplayMatch the Code Numbers Enter the Code ModeCode the Meter Checking the System with PocketScan Control Solution Do a control solution test Important Control Solution Test Information Insert Test Strip Result Appears in 15 Seconds Apply Control SolutionAt UK 0800 Republic of Ireland 1800 Comparing control solution resultsTesting Your Blood Insert a Lancet in the Penlet II Automatic Blood Sampler Getting a Drop of BloodCock the Penlet II Sampler Lance Your Finger Wash Your HandsRemove the Lancet Step-by-Step Test Procedure Accurate Results in Just 15 Seconds Apply SampleExample Special MessagesUsing the Meter Memory Recall Test Results Data Downloading Exit the Memory ModeResults References Batteries MaintenanceSymbol appears on the display Display Messages and PROBLEM- Solving Guide Message What IT Means Result. At the end of the count Message What IT Means Message What IT Means Action That Blood Sample was Tests were performed within This period Select the appropriate unit of measurement Probable Cause What to do Calibration Plasma/Serum Test Time 15 secondsAutomatic Shutoff Two minutes after last user action Operating RangesSet the Year Changing the DateSet the Day Set the Month Set the Hour Changing the TimeSet the Minutes Select mmol/L or mg/dL Exit the Setting ModePage Test Page 1998 Visit the LifeScan website at