Lincoln Electric IM524-D manual Figure D.1 Resistor Locations

Page 37

D-2

D-2

MAINTENANCE

FIGURE D.1 – RESISTOR LOCATIONS

5 PAIRS OF RESISTORS

CHECK VOLTAGES BETWEEN EACH TERMINAL AND FROM EACH RESISTOR TO CASE GROUND

5.Locate two sets of two resistors on the left side of the machine and three sets of two resistors on the right side of the machine. See Figure D.1. Do not touch the resistors or any other internal machine component. Using a DC voltmeter, check for any DC voltage that may be present across the termi- nals of each resistor and from each resistor to case ground (20 measurements in all). If a voltage is present, be careful not to touch these resistors.

WARNING

ELECTRIC SHOCK can kill.

Proceed with caution being care- ful not to touch any internal machine components during the discharge procedure.

POWER WAVE 450

Image 37
Contents For use with machines having Code Numbers Safety Depends on YouSafety Electric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Thank You Table of Contents Section D Section CSection E Section FPulse Pulse and Background Current Range Technical Specifications Power WaveFrequency High Frequency Precautions Safety PrecautionsSelect Suitable Location Input ConnectionsInput Fuse and Supply Wire Considerations Input Power ConnectionsInput Voltage Reconnect Procedure Power WaveOutput Connections Wire Feeder ConnectionsWork and Electrode Cable Connections Water Cooler ConnectionsOperating Instructions Safety InstructionsSave process information if desired Select your process informationGeneral Description Case Front Controls Controls and SettingsOperating Overlays Installing AN OverlayOverview Overlay Overlay TypesName Overlay ID Number = PULSE, GMAW, FCAW, and STICK/TIG Process Selection OverlayOperation Then Figure B.5 Weld from Memory Overlay Weld from Memory OverlayFigure B.6 Weld from MEMORY, Dual Procedure Overlay Weld from MEMORY, Dual Procedure OverlayOperation Position Procedure Dual Wire FEEDERS, Dual Procedure Overlay OptionalRecall from Memory KEY Memory Location Numbers Limits Overlay OptionalSET Limit KEY Limit UP / Down Keys Operation Figure B.9 Setup Overlay Setup Overlay+/- Polarity KEY Wire Feeder Setup DescriptionPositive Voltage Sensing Polarity Flux Cored ARC Welding Fcaw and Gmaw Procedures Overview of Welding ProceduresPulse Procedures ProceduresGmaw Table B.3 Adjustble ParametersFcaw Gmaw StickOverload Protection Pulse WeldingWire Feeder Setup OPTIONS/ACCESSORIESTable C.1 Recommended Guns for USE With Power Wave Guns and CablesPriming the Cooler Recommended CoolantsInput Filter Capacitor DIS Charge Procedure Routine and Periodic MaintenanceFigure D.1 Resistor Locations Locate the #9 and #12 terminals, identified by Discharge labels, on each of the four SwitchConnected Preventive Maintenance Removing and Installing the G3503 Cooler G3503- Installation or SER Vice Tool UsageG3503- Cooler Service G3503- Cooler Periodic MaintenanceFigure D.4 General Component Locations Locate Problem Symptom HOW to USE Troubleshooting GuideConsult Local Authorized Field Service Facility Perform External RecommendAuthorized Field Service Facility Troubleshooting GuideSists, contact your local Lincoln Play fans run Check circuit breaker 5-amp Observe Safety Guidelines Controls and Settings Power-up Inspect the overlay bar code Saved in memory are different Check for proper shielding gas $700.00 Basic CoursePrecaucion Aviso DE