SAFETY

iii

WELDING SPARKS can cause fire or explosion.

6.a. Remove fire hazards from the welding area. If this is not possible, cover them to prevent the welding sparks from starting a fire. Remember that welding sparks and hot

materials from welding can easily go through small cracks and openings to adjacent areas. Avoid welding near hydraulic lines. Have a fire extinguisher readily available.

6.b. Where compressed gases are to be used at the job site, special precautions should be used to prevent hazardous situations. Refer to “Safety in Welding and Cutting” (ANSI Standard Z49.1) and the operating information for the equipment being used.

6.c. When not welding, make certain no part of the electrode circuit is touching the work or ground. Accidental contact can cause overheating and create a fire hazard.

6.d. Do not heat, cut or weld tanks, drums or containers until the proper steps have been taken to insure that such procedures will not cause flammable or toxic vapors from substances inside. They can cause an explosion even though they have been “cleaned”. For information, purchase “Recommended Safe Practices for the Preparation for Welding and Cutting of Containers and Piping That Have Held Hazardous Substances”, AWS F4.1 from the American Welding Society (see address above).

6.e. Vent hollow castings or containers before heating, cutting or welding. They may explode.

6.f. Sparks and spatter are thrown from the welding arc. Wear oil free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes and a cap over your hair. Wear ear plugs when welding out of position or in confined places. Always wear safety glasses with side shields when in a welding area.

6.g. Connect the work cable to the work as close to the welding area as practical. Work cables connected to the building framework or other locations away from the welding area increase the possibility of the welding current passing through lifting chains, crane cables or other alternate circuits. This can create fire hazards or overheat lifting chains or cables until they fail.

6.h. Also see item 1.c.

CYLINDER may explode if damaged.

7.a. Use only compressed gas cylinders

containing the correct shielding gas for the process used and properly operating regulators designed for the gas and

pressure used. All hoses, fittings, etc. should be suitable for the application and maintained in good condition.

7.b. Always keep cylinders in an upright position securely chained to an undercarriage or fixed support.

7.c. Cylinders should be located:

Away from areas where they may be struck or subjected to physical damage.

A safe distance from arc welding or cutting operations and any other source of heat, sparks, or flame.

7.d. Never allow the electrode, electrode holder or any other electrically “hot” parts to touch a cylinder.

7.e. Keep your head and face away from the cylinder valve outlet when opening the cylinder valve.

7.f. Valve protection caps should always be in place and hand tight except when the cylinder is in use or connected for use.

7.g. Read and follow the instructions on compressed gas cylinders, associated equipment, and CGA publication P-l, “Precautions for Safe Handling of Compressed Gases in Cylinders,” available from the Compressed Gas Association 1235 Jefferson Davis Highway, Arlington, VA 22202.

FOR ELECTRICALLY powered equipment.

8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment.

8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.

8.c. Ground the equipment in accordance with the U.S. National Electrical Code and the manufacturer’s recommendations.

Mar ‘95

Image 4
Contents Safety Depends on You For use with machines having Code NumbersSafety Electric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Thank You Table of Contents Section C Section DSection E Section FPulse Pulse and Background Current Range Technical Specifications Power WaveFrequency Safety Precautions High Frequency PrecautionsSelect Suitable Location Input ConnectionsInput Power Connections Input Fuse and Supply Wire ConsiderationsInput Voltage Reconnect Procedure Power WaveWire Feeder Connections Output ConnectionsWork and Electrode Cable Connections Water Cooler ConnectionsSafety Instructions Operating InstructionsSelect your process information Save process information if desiredGeneral Description Controls and Settings Case Front ControlsOperating Overlays Installing AN OverlayOverview Overlay Overlay TypesName PULSE, GMAW, FCAW, and STICK/TIG Process Selection Overlay Overlay ID Number =Operation Then Weld from Memory Overlay Figure B.5 Weld from Memory OverlayWeld from MEMORY, Dual Procedure Overlay Figure B.6 Weld from MEMORY, Dual Procedure OverlayOperation Dual Wire FEEDERS, Dual Procedure Overlay Optional Position ProcedureRecall from Memory KEY Memory Location Numbers Limits Overlay OptionalSET Limit KEY Limit UP / Down Keys Operation Setup Overlay Figure B.9 Setup OverlayWire Feeder Setup Description +/- Polarity KEYPositive Voltage Sensing Polarity Overview of Welding Procedures Flux Cored ARC Welding Fcaw and Gmaw ProceduresPulse Procedures ProceduresTable B.3 Adjustble Parameters GmawFcaw Gmaw StickPulse Welding Overload ProtectionOPTIONS/ACCESSORIES Wire Feeder SetupTable C.1 Recommended Guns for USE With Power Wave Guns and CablesRecommended Coolants Priming the CoolerRoutine and Periodic Maintenance Input Filter Capacitor DIS Charge ProcedureFigure D.1 Resistor Locations Locate the #9 and #12 terminals, identified by Discharge labels, on each of the four SwitchConnected Preventive Maintenance G3503- Installation or SER Vice Tool Usage Removing and Installing the G3503 CoolerG3503- Cooler Periodic Maintenance G3503- Cooler ServiceFigure D.4 General Component Locations HOW to USE Troubleshooting Guide Locate Problem SymptomConsult Local Authorized Field Service Facility Perform External RecommendAuthorized Field Service Facility Troubleshooting GuideSists, contact your local Lincoln Play fans run Check circuit breaker 5-amp Observe Safety Guidelines Controls and Settings Power-up Inspect the overlay bar code Saved in memory are different Check for proper shielding gas Basic Course $700.00Precaucion Aviso DE