TROUBLESHOOTING

 

 

TROUBLESHOOTING GUIDE

 

 

Observe Safety Guidelines

 

 

 

detailed in the beginning of this manual.

 

PROBLEMS

POSSIBLE AREAS OF

 

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

The Beeper (Piezoelectric Buzzer) cannot be

1. Background noise may be too loud for user

 

 

 

 

heard machine operating normally.

to hear beeper.

 

 

 

 

 

 

 

 

 

 

The welding parameters that were

1. Make certain that a remote control unit is

 

 

 

 

saved in memory are different

not connected. When a remote control unit is

 

 

 

 

when recalled.

used, the weld parameters are set by the

 

 

 

 

 

remote control potentiometers.

 

 

 

 

 

 

 

 

 

 

The water cooler does not turn on.

1. Make sure that the water cooler has been

 

 

 

 

enabled. Refer to the Setup Overlay descrip-

 

 

 

 

 

 

 

 

 

 

tion in the Operation Section of this manual.

 

 

 

2.The coolers circuit breaker may have tripped.

3.If the water cooler is enabled but generates insufficient coolant flow rate, the machine will beep loudly and the water cooler will shut down. In this case, prime the water cooler. Refer to the Setup Overlay description in the Operation Section of this manual.

The machine beeps without the

If the water cooler is enabled and the flow

If all recommended possible areas

keys being pressed.

of misadjustments have been

switch inside the water cooler opens (due to

 

checked and the problem per-

 

inadequate coolant flow rate), the machine

 

sists, contact your local Lincoln

 

indicates this by beeping. This happens

 

Authorized Field Service Facility.

 

regardless of the overlay placed on the

 

 

 

machine. In this case do the following:

 

 

1. Turn the machine off and on a couple of

 

 

times and see if the beeping continues. If the

 

 

flow rate dropped momentarily then turning

 

 

the machine off and on eliminates the beep-

 

 

ing. A momentary

drop in flow rate could be

 

 

due to someone stepping on the water cooler

 

 

hose, for example.

 

 

2 Check the water cooler and accessory hoses for kinks, internal obstructions or block- age, or ruptures. If such problems were found then correct them and turn the machine off and on to check if the beeping has been elimi- nated.

3.Check the water cooler fluid level. Low coolant level could cause the flow rate to drop.

4.Prime the water cooler. Refer to the Setup Overlay section of this manual for instructions.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact your local authorized Lincoln Electric Field Service Facility for technical assistance.

POWER WAVE 450

Image 49
Contents For use with machines having Code Numbers Safety Depends on YouSafety Electric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Thank You Table of Contents Section D Section CSection E Section FPulse Pulse and Background Current Range Technical Specifications Power WaveFrequency High Frequency Precautions Safety PrecautionsSelect Suitable Location Input ConnectionsInput Fuse and Supply Wire Considerations Input Power ConnectionsInput Voltage Reconnect Procedure Power WaveOutput Connections Wire Feeder ConnectionsWork and Electrode Cable Connections Water Cooler ConnectionsOperating Instructions Safety InstructionsSave process information if desired Select your process informationGeneral Description Case Front Controls Controls and SettingsOperating Overlays Installing AN OverlayOverview Overlay Overlay TypesName Overlay ID Number = PULSE, GMAW, FCAW, and STICK/TIG Process Selection OverlayOperation Then Figure B.5 Weld from Memory Overlay Weld from Memory OverlayFigure B.6 Weld from MEMORY, Dual Procedure Overlay Weld from MEMORY, Dual Procedure OverlayOperation Position Procedure Dual Wire FEEDERS, Dual Procedure Overlay OptionalRecall from Memory KEY Memory Location Numbers Limits Overlay OptionalSET Limit KEY Limit UP / Down Keys Operation Figure B.9 Setup Overlay Setup Overlay+/- Polarity KEY Wire Feeder Setup DescriptionPositive Voltage Sensing Polarity Flux Cored ARC Welding Fcaw and Gmaw Procedures Overview of Welding ProceduresPulse Procedures ProceduresGmaw Table B.3 Adjustble ParametersFcaw Gmaw StickOverload Protection Pulse WeldingWire Feeder Setup OPTIONS/ACCESSORIESTable C.1 Recommended Guns for USE With Power Wave Guns and CablesPriming the Cooler Recommended CoolantsInput Filter Capacitor DIS Charge Procedure Routine and Periodic MaintenanceFigure D.1 Resistor Locations Locate the #9 and #12 terminals, identified by Discharge labels, on each of the four SwitchConnected Preventive Maintenance Removing and Installing the G3503 Cooler G3503- Installation or SER Vice Tool UsageG3503- Cooler Service G3503- Cooler Periodic MaintenanceFigure D.4 General Component Locations Locate Problem Symptom HOW to USE Troubleshooting GuideConsult Local Authorized Field Service Facility Perform External RecommendAuthorized Field Service Facility Troubleshooting GuideSists, contact your local Lincoln Play fans run Check circuit breaker 5-amp Observe Safety Guidelines Controls and Settings Power-up Inspect the overlay bar code Saved in memory are different Check for proper shielding gas $700.00 Basic CoursePrecaucion Aviso DE