Lincoln Electric IM524-D manual Play fans run Check circuit breaker 5-amp

Page 45

E-3

E-3

TROUBLESHOOTING

TROUBLESHOOTING GUIDE

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

OUTPUT PROBLEMS

 

Machine has no output no fans

1. Check for proper input voltage

 

no display. Main input fuses are

connections.

 

open, indicating excessive input

2. Make certain the reconnect

 

current draw.

 

panel is configured properly for the

 

 

 

 

applied voltage.

 

 

3. Replace the input fuses with

 

 

proper size and ratings. If the

 

 

fuses fail again, contact your local

 

 

Lincoln Authorized Field Service

 

 

Facility.

If all recommended possible areas

 

 

 

 

of misadjustments have been

 

 

checked and the problem per-

Machine has no output no dis-

 

sists, contact your local Lincoln

play fans run.

1. Check circuit breaker (5-amp)

Authorized Field Service Facility.

 

located on the front panel. Reset if

 

 

necessary.

 

Machine has no output no dis-

1. Remove the feeder control cable

play fans run circuit breaker

from the machine. If symptoms

(5-amp) repeatedly trips.

disappear, feeder or control cable

 

 

is faulty.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact your local authorized Lincoln Electric Field Service Facility for technical assistance.

POWER WAVE 450

Image 45
Contents For use with machines having Code Numbers Safety Depends on YouSafety Electric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Thank You Table of Contents Section D Section CSection E Section FTechnical Specifications Power Wave Pulse Pulse and Background Current RangeFrequency High Frequency Precautions Safety PrecautionsSelect Suitable Location Input ConnectionsInput Fuse and Supply Wire Considerations Input Power ConnectionsInput Voltage Reconnect Procedure Power WaveOutput Connections Wire Feeder ConnectionsWork and Electrode Cable Connections Water Cooler ConnectionsOperating Instructions Safety InstructionsSave process information if desired Select your process informationGeneral Description Case Front Controls Controls and SettingsInstalling AN Overlay Operating OverlaysOverview Overlay Types OverlayName Overlay ID Number = PULSE, GMAW, FCAW, and STICK/TIG Process Selection OverlayOperation Then Figure B.5 Weld from Memory Overlay Weld from Memory OverlayFigure B.6 Weld from MEMORY, Dual Procedure Overlay Weld from MEMORY, Dual Procedure OverlayOperation Position Procedure Dual Wire FEEDERS, Dual Procedure Overlay OptionalLimits Overlay Optional Recall from Memory KEY Memory Location NumbersSET Limit KEY Limit UP / Down Keys Operation Figure B.9 Setup Overlay Setup Overlay+/- Polarity KEY Wire Feeder Setup DescriptionPositive Voltage Sensing Polarity Flux Cored ARC Welding Fcaw and Gmaw Procedures Overview of Welding ProceduresPulse Procedures ProceduresGmaw Table B.3 Adjustble ParametersFcaw Gmaw StickOverload Protection Pulse WeldingWire Feeder Setup OPTIONS/ACCESSORIESTable C.1 Recommended Guns for USE With Power Wave Guns and CablesPriming the Cooler Recommended CoolantsInput Filter Capacitor DIS Charge Procedure Routine and Periodic MaintenanceFigure D.1 Resistor Locations Discharge labels, on each of the four Switch Locate the #9 and #12 terminals, identified byConnected Preventive Maintenance Removing and Installing the G3503 Cooler G3503- Installation or SER Vice Tool UsageG3503- Cooler Service G3503- Cooler Periodic MaintenanceFigure D.4 General Component Locations Locate Problem Symptom HOW to USE Troubleshooting GuideConsult Local Authorized Field Service Facility Perform External RecommendTroubleshooting Guide Authorized Field Service FacilitySists, contact your local Lincoln Play fans run Check circuit breaker 5-amp Observe Safety Guidelines Controls and Settings Power-up Inspect the overlay bar code Saved in memory are different Check for proper shielding gas $700.00 Basic CoursePrecaucion Aviso DE