Lincoln Electric IM10023 manual Interfacing to the MAXsa 10 CON, Troller

Page 11

A-4

INSTALLATION

A-4

 

 

 

INTERFACING TO THE MAXsa™ 10 CON-

TROLLER

The MAXsa™ 10 CONTROLLER is a versatile con- troller. The User Interface can be removed and used as a hand-held pendant. Most circuits can be accessed through the screwless terminal strip. The auxiliary relays can control standard Lincoln equipment, or they can be used to control any other auxiliary equipment custom controls. PLC interfacing to control starting, stopping, motion, etc, can be accomplished with ease.

Using the Controller as a Hand-held Pendant:

1.Remove the 4 screws from the MAXsa™ 10 CON- TROLLER that hold the cover. See Figure A.2.

2.Remove the 2 screws that hold the pendant in the brackets. Use the acccess holes shown.

3.Extend the control cable as needed with an Arc Link cable of appropriate length. See Figure A.2

FIGURE A.2 - HAND HELD PENDANT

1

2

Front Vie w

 

Cov

r eorme dev

Cov rseweScr

Pendant

(4 places)

Screws

 

( 2 Places)

Access

Hol e

eCov

3

K1543-xx

or K2683-xx Arclink Cba le (Optional)

MAXsa™ 10 CONTROLLER

Image 11
Contents Controller Safety Electric Shock can kill Welding and Cutting Sparks can Cause fire or explosion Précautions DE Sûreté Thank You Table of Contents Technical Specifications MAXsa 10 Controller InstallationSafety Precaution Figure A.1 MAXsa 10 Connections Troller Interfacing to the MAXsa 10 CONFigure A.3 Figure A.4 Controlling NON-LINCOLN Equipment Stop Input Shutdown InputsFigure A.6 Connection Diagram Single ARC System Definitions of Welding Modes Safety PrecautionsDesign Features OperationCommon Basic Equipment Packages Recommended Processes and EquipmentGeneral Physical Description General Functional Description200 Setting Feed FORWARD/REVERSE POWER-UP SequenceWire Feeder Setup Offset Adjust Changing and Setting Weld ModesFrequency Adjust Balance AdjustTable B.1 Phase Relationship ARC Weld Mode SearchingSearching for a Weld Mode Multiple ARC ConfigurationStart Options Arc Delay TimeWeld Sequence Start Options OperationDownslope Time END OptionsEND Options Operation Preference Selection Accessing the Setup MenuAccess Preference Change Parameter DefinitionUser Defined Parameters Shutdown 2 Function Select Wire Drive Gear Ratio100 View Diagnostics? Parameter Definition Hot-Inch Touch Sense Option103 View Software Version Information 107 View Power Source ProtocolParameter Definition 101 View Event Logs 102 View Fatal LogsParameter Definition 502 Memory Change Lockout 503 Memory Button Disable504 Mode Select Panel Lock 505 Setup Menu LockLockout / Security Parameter Definition 506 Set User Interface Passcode509 UI Master Lockout Touch SenseFigure B.7 Making a Weld Making a WeldMulti Procedure Welding Using the Memory OptionNaming a Saved Procedure CC DC + Saving a Procedure to a Memory LocationRecalling a Procedure from a Memory Location Steel 1/8Setting Limits Optional Limit SetupFollow these steps AccessoriesPeriodic Maintenance Calibration Specification MaintenanceRoutine Maintenance HOW to USE Troubleshooting Guide TroubleshootingTable E.1 Using the Status LED to Troubleshoot System ProblemsArclink System Error Codes Troubleshooting Verify correct sense lead connection Output Disabled Output Problems Troubleshooting Enhanced Diagram DiagramsL13444 Dimension PrintPrecaucion Warnung