| TROUBLESHOOTING | |||||
|
|
|
|
|
|
|
|
Typical User Interface 3 digit error codes (not blinked on the status LED). | |||||||
|
|
|
|
|
|
| |
Error | Source | UI Text |
|
| Reason | ||
Code |
|
|
|
|
|
| |
|
|
|
|
|
| ||
283 |
|
| (Varies based on the | Internal Error. Collect all displayed values and contact | |||
|
|
| error type and who | Lincoln Electric Service Department. | |||
|
|
| caused the error) |
|
|
|
|
285 |
|
|
|
| |||
|
| N/A | UI memory could not be restored. Contact Lincoln | ||||
|
|
|
| Electric Service Department for further support. | |||
612 |
| User Interface | {" Phase Gen Init "}, | 1 = | Initializing Phase Generator |
| |
|
|
| {"Duplicate Arc # "}, | 2 | = | Duplicate Arc #'s found | |
|
|
| {" Mult Lead Arcs "}, | 3 | = | Mult Lead Arcs found | |
|
|
| {" Missing an Arc "}, |
| 4 | = Missing a Trail Arc | |
|
|
| {" Too Many Arcs "}, |
| 5 = Too Many Arcs | ||
|
|
| {"Missing Lead Arc"}, |
| 6 | = Missing Lead Arc | |
|
|
| {" Missing an Arc "} | 7 = Trail Arc dropped communication with Lead Arc | |||
|
|
|
|
|
|
|
|
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
OUTPUT PROBLEMS
The feeder does not power up - no | 1. The Power Wave power source is |
display, no feed. | OFF. Turn ON the Power Wave |
| source. |
2.The circuit breaker for the wire feeder on power source has tripped. Reset the circuit break- ers.
3.The control cable may be loose
or damaged. Tighten, repair or If all recommended possible areas of
replace the control cable. | misadjustment have been checked |
| and the problem persists, Contact |
4. The power switch is damaged. your local Lincoln Authorized Field | |
Replace the power switch. | Service Facility. |
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
MAXsa™ 10 CONTROLLER