Lincoln Electric IM10023 Parameter Definition 502 Memory Change Lockout, Memory Button Disable

Page 28

B-13

 

OPERATION

B-13

 

 

 

 

 

 

 

 

 

USER DEFINED PARAMETERS (CONT.)

 

 

 

Parameter

Definition

 

 

 

 

 

 

 

 

P.502

Memory Change Lockout

 

 

Determines if the memories can be overwritten with new contents. No = Memories can be saved and limits can be configured (default).

Yes = Memories cannot be changed - saving is prohibited and limits cannot be re-configured. This parameter can only be accessed using Power Wave Manager software.

P.503

Memory Button Disable

 

Disables the specified memory button(s). When a memory is disabled, welding procedures can-

 

not be restored from or saved to that memory. If an attempt is made to save or restore a dis-

 

abled memory, a message will be displayed on the lower display indicating the memory number

 

is disabled. In multi-head systems, this parameter disables the same memory buttons on both

 

feed heads. This parameter can only be accessed using Power Wave Manager software.

P.504

Mode Select Panel Lock

 

Selects between several Mode Select Panel lockout preferences. When a Mode Select Panel

 

selection is locked and an attempt is made to change that parameter, a message will be dis-

 

played on the lower display indicating the parameter is locked.

 

All MSP Options Unlocked = All adjustable parameters on the Mode Select Panel are

 

unlocked.

 

All MSP Options Locked = All knobs and buttons on the Mode Select Panel are locked.

 

Start & End Options Locked = The Start and End parameters on the Mode Select Panel are

 

locked, all others are unlocked.

 

Weld Mode Option Locked = The weld mode cannot be changed from the Mode Select Panel,

 

all others Mode Select Panel settings are unlocked.

 

Wave Control Options Locked = The Wave Control parameters on the Mode Select Panel are

 

locked, all others are unlocked.

 

Start, End, Wave Options Locked = The Start, End and Wave Control parameters on the

 

Mode.

 

Select Panel are locked, all others are unlocked.

 

Start, End, Mode Options Locked = The Start, End and Weld Mode Select parameters on the

 

Mode.

 

Select Panel are locked, all others are unlocked.

 

This parameter can only be accessed using Power Wave Manager software.

P.505

Setup Menu Lock

 

Determines if the setup parameters can be modified by the operator without entering a pass-

 

code.

 

No = The operator can change any set menu parameter without first entering the passcode

 

even if the passcode is non-zero (default).

 

Yes = The operator must enter the passcode (if the passcode is non-zero) in order to change

 

any setup menu parameters.

 

This parameter can only be accessed using Power Wave Manager software.

 

 

MAXsa™ 10 CONTROLLER

Image 28
Contents Controller Safety Electric Shock can kill Welding and Cutting Sparks can Cause fire or explosion Précautions DE Sûreté Thank You Table of Contents Installation Technical Specifications MAXsa 10 ControllerSafety Precaution Figure A.1 MAXsa 10 Connections Interfacing to the MAXsa 10 CON TrollerFigure A.3 Figure A.4 Controlling NON-LINCOLN Equipment Shutdown Inputs Stop InputFigure A.6 Connection Diagram Single ARC System Safety Precautions Design FeaturesOperation Definitions of Welding ModesRecommended Processes and Equipment General Physical DescriptionGeneral Functional Description Common Basic Equipment Packages200 Wire Feeder Setup POWER-UP SequenceSetting Feed FORWARD/REVERSE Changing and Setting Weld Modes Frequency AdjustBalance Adjust Offset AdjustWeld Mode Searching Searching for a Weld ModeMultiple ARC Configuration Table B.1 Phase Relationship ARCArc Delay Time Weld SequenceStart Options Operation Start OptionsEND Options Operation END OptionsDownslope Time Accessing the Setup Menu Access Preference ChangeParameter Definition Preference SelectionUser Defined Parameters Wire Drive Gear Ratio 100 View Diagnostics?Parameter Definition Hot-Inch Touch Sense Option Shutdown 2 Function Select107 View Power Source Protocol Parameter Definition 101 View Event Logs102 View Fatal Logs 103 View Software Version Information503 Memory Button Disable 504 Mode Select Panel Lock505 Setup Menu Lock Parameter Definition 502 Memory Change LockoutParameter Definition 506 Set User Interface Passcode 509 UI Master LockoutTouch Sense Lockout / SecurityMaking a Weld Figure B.7 Making a WeldNaming a Saved Procedure Using the Memory OptionMulti Procedure Welding Saving a Procedure to a Memory Location Recalling a Procedure from a Memory LocationSteel 1/8 CC DC +Optional Limit Setup Setting LimitsAccessories Follow these stepsRoutine Maintenance MaintenancePeriodic Maintenance Calibration Specification Troubleshooting HOW to USE Troubleshooting GuideUsing the Status LED to Troubleshoot System Problems Table E.1Arclink System Error Codes Troubleshooting Verify correct sense lead connection Output Disabled Output Problems Troubleshooting Diagrams Enhanced DiagramDimension Print L13444Precaucion Warnung