| OPERATION | ||||
|
|
|
|
|
|
|
|
| USER DEFINED PARAMETERS (CONT.) |
|
|
| Parameter | Definition |
|
| |
|
|
|
|
| |
| P.502 | Memory Change Lockout |
|
|
Determines if the memories can be overwritten with new contents. No = Memories can be saved and limits can be configured (default).
Yes = Memories cannot be changed - saving is prohibited and limits cannot be
P.503 | Memory Button Disable |
| Disables the specified memory button(s). When a memory is disabled, welding procedures can- |
| not be restored from or saved to that memory. If an attempt is made to save or restore a dis- |
| abled memory, a message will be displayed on the lower display indicating the memory number |
| is disabled. In |
| feed heads. This parameter can only be accessed using Power Wave Manager software. |
P.504 | Mode Select Panel Lock |
| Selects between several Mode Select Panel lockout preferences. When a Mode Select Panel |
| selection is locked and an attempt is made to change that parameter, a message will be dis- |
| played on the lower display indicating the parameter is locked. |
| All MSP Options Unlocked = All adjustable parameters on the Mode Select Panel are |
| unlocked. |
| All MSP Options Locked = All knobs and buttons on the Mode Select Panel are locked. |
| Start & End Options Locked = The Start and End parameters on the Mode Select Panel are |
| locked, all others are unlocked. |
| Weld Mode Option Locked = The weld mode cannot be changed from the Mode Select Panel, |
| all others Mode Select Panel settings are unlocked. |
| Wave Control Options Locked = The Wave Control parameters on the Mode Select Panel are |
| locked, all others are unlocked. |
| Start, End, Wave Options Locked = The Start, End and Wave Control parameters on the |
| Mode. |
| Select Panel are locked, all others are unlocked. |
| Start, End, Mode Options Locked = The Start, End and Weld Mode Select parameters on the |
| Mode. |
| Select Panel are locked, all others are unlocked. |
| This parameter can only be accessed using Power Wave Manager software. |
P.505 | Setup Menu Lock |
| Determines if the setup parameters can be modified by the operator without entering a pass- |
| code. |
| No = The operator can change any set menu parameter without first entering the passcode |
| even if the passcode is |
| Yes = The operator must enter the passcode (if the passcode is |
| any setup menu parameters. |
| This parameter can only be accessed using Power Wave Manager software. |
|
|
MAXsa™ 10 CONTROLLER