Lincoln Electric IM10023 manual Installation, Technical Specifications MAXsa 10 Controller

Page 8

A-1

 

 

 

 

INSTALLATION

 

 

A-1

 

 

 

 

 

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS: MAXsa10 CONTROLLER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT VOLTAGE & CURRENT

 

PHYSICAL SIZE•

TEMPERATURE RATING

 

 

 

 

 

 

Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Voltage*

-- Input Amps*

 

Height

Width

 

Depth

 

Weight

Operating

Storage

 

 

 

 

 

 

 

 

 

 

 

 

K2814-1

40VDC

1.0

 

15.0in.

13.0 in

 

4.0 in.

 

25 Lbs

14°F to 104°F

-40°F to 185°F

 

 

 

 

 

(381 mm)

(259 mm)

 

(102 mm)

 

(11.3 Kg.)

(-10°C to 40°C)

(-40°C to 85°C)

 

 

 

 

 

 

 

 

 

 

 

 

 

*When not driving a motor.

MAXsa™ 10 CONTROLLER

Image 8
Contents Controller Safety Electric Shock can kill Welding and Cutting Sparks can Cause fire or explosion Précautions DE Sûreté Thank You Table of Contents Installation Technical Specifications MAXsa 10 ControllerSafety Precaution Figure A.1 MAXsa 10 Connections Interfacing to the MAXsa 10 CON TrollerFigure A.3 Figure A.4 Controlling NON-LINCOLN Equipment Shutdown Inputs Stop InputFigure A.6 Connection Diagram Single ARC System Safety Precautions Design FeaturesOperation Definitions of Welding ModesRecommended Processes and Equipment General Physical DescriptionGeneral Functional Description Common Basic Equipment Packages200 Setting Feed FORWARD/REVERSE POWER-UP SequenceWire Feeder Setup Changing and Setting Weld Modes Frequency AdjustBalance Adjust Offset AdjustWeld Mode Searching Searching for a Weld ModeMultiple ARC Configuration Table B.1 Phase Relationship ARCArc Delay Time Weld SequenceStart Options Operation Start OptionsDownslope Time END OptionsEND Options Operation Accessing the Setup Menu Access Preference ChangeParameter Definition Preference SelectionUser Defined Parameters Wire Drive Gear Ratio 100 View Diagnostics?Parameter Definition Hot-Inch Touch Sense Option Shutdown 2 Function Select107 View Power Source Protocol Parameter Definition 101 View Event Logs102 View Fatal Logs 103 View Software Version Information503 Memory Button Disable 504 Mode Select Panel Lock505 Setup Menu Lock Parameter Definition 502 Memory Change LockoutParameter Definition 506 Set User Interface Passcode 509 UI Master LockoutTouch Sense Lockout / SecurityMaking a Weld Figure B.7 Making a WeldMulti Procedure Welding Using the Memory OptionNaming a Saved Procedure Saving a Procedure to a Memory Location Recalling a Procedure from a Memory LocationSteel 1/8 CC DC +Optional Limit Setup Setting LimitsAccessories Follow these stepsPeriodic Maintenance Calibration Specification MaintenanceRoutine Maintenance Troubleshooting HOW to USE Troubleshooting GuideUsing the Status LED to Troubleshoot System Problems Table E.1Arclink System Error Codes Troubleshooting Verify correct sense lead connection Output Disabled Output Problems Troubleshooting Diagrams Enhanced DiagramDimension Print L13444Precaucion Warnung